Group Selection Page HELP Controls Group Data Analysis Group ITDM WP76 DET Vacuum EEE WP78 FXE SPB MID HED SQS SXP Sample Environment Operation PSPO XO TS Migrated2Zulip
Technical integration and coordination SASE1 Status and SASE3 Readiness
  Technical integration and coordination logbook, Contact: A. Violante, G. Wellenreuther, Page 19 of 31  Not logged in ELOG logo
ID Date Authordown Location Severity Subject
  527   03 Jul 2024, 09:54 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 03.07.2024
General Announcement:
- Tunnels have been closed and the Interlock Tests required by the legislators are ongoing.
- Eric Boyd informs that next Monday two hutches have to be searched for the Interlock Tests, one at MID and one at FXE. An e-mail will be sent to the instruments.
- J. Sztuk-Dambietz asks on the DAQ for DET to do not close the proposals yet; Steffen H. informs that a fix is on the way and will be fixed and running. Proposals will not be closed until the deployment.

CTRL:
- Deployment of Karabo last week.
- Announcement: re-deploy Karabo Beckhoff devices to rollback have to be done as new feature was causing problems (related to the unit values). 
Today 2PM for tunnels and Laser topics; for instruments will be later organized. A brief restart is expected.

DA:
- Nothing to report.

EEE:
- Working with CTRL to re-deploy Karabo devices for digitizers. This is ongoing and will be available later today or tomorrow.

VAC:
- Not present.

XPD:
- Completed tasks on tunnels.
- Yesterday work in Gotthard-II detector at SA2 (Hirex) was found detector does not work. CTRL and DET helped and detector was moved out of tunnel. There is no HIREX available in SA2. 
Also power supply for HIREX in SA1 has to be worked.

DET:
- Working on the Gotthard-II with XPD.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- All good so far.

UNSYS:
- Everything is fine.

SPB:
- Nothing to report.

FXE:
- Nothing to report.

MID:
- All fine at MID.

HED:
- Nothing to report.

SCS:
- Not present.

SQS:
- Not present.

SXP:
- Nothing to report.
  528   08 Jul 2024, 08:46 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 08.07.2024
General Announcement:
- Eric Boyd comments on Interlock tests: today FXE and MID hutches are being searched for ~30 mins. Please contact Eric in case you find lights ON. 
For tomorrow, Tuesday: OFF buttons will be tested and jumped in SA1/SA3 instruments and on Wednesday the SA2 instruments. Access is restricted and e-mail will be sent to communicate when people are 
allowed to resume access/work. 
Also please clean up the hutches for the inspection and tests.

CTRL:
- Nothing to report; Karabo redeployment went well last week.

DA:
- Nothing to report.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- XTD6 tunnel access is needed for HIREX.

DET:
- Intervention at SPB AGIPD: modules were swept, severe effect due to radiation (one module not working). One module was swept in the quadrant. It was successful.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- Some surprises but under control.

UNSYS:
- All fine.

SPB:
- All fine.

FXE:
- Software and firmware updates with detectors taking place.

MID:
- All fine at MID.

HED:
- Nothing to report.

SCS:
- Nothing to report.

SQS:
- Nothing to report.

SXP:
- Not present.
  529   10 Jul 2024, 09:48 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 10.07.2024
General Announcement:
- Frank Poppe asks for an available time for a tour in experimental Hall and tunnels. It will be discussed offline with XO.

CTRL:
- Nothing to report.

DA:
- Nothing to report.

EEE:
- Nothing to report.

VAC:
- XTD6 was searched yesterday evening for extra interlock tests. This was finished and tunnel will be opened again today for XPD work.

XPD:
- Work on HIREX is progressing and estimate to install back in tunnel is Thursday or Friday.

DET:
- Marco R. is working on the Gotthard-II of Hirex; also DET is preparing for next Run.

ITDM: 
- Migration of XFEL gateway will be done on late Thursday. Karabo database will also be done. Announcement will be sent.

XRO:
- Not present.

LAS:
- Not present.

UNSYS:
- Everything is fine.

SPB:
- Nothing to report.

FXE:
- Nothing to report.

MID:
- All fine at MID.

HED:
- Nothing to report.

SCS:
- Nothing to report; transport with Hall crew is planned for today.

SQS:
- Nothing to report.

SXP:
- Not present.
  530   15 Jul 2024, 09:39 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 15.07.2024
General Announcement:
- The User Operation Meetings will restart next Friday 19.07.

CTRL:
- Proceeding with bring up days.

DA:
- Busy with bring up days.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- Not present.
- As PRC, Raul Villanueva informs that activities in XTD6 are planned to be finished by tomorrow, Tuesday.

DET:
- HIREX / Gotthard-II inSA2: it is fixed and installation is ongoing.

ITDM: 
- Nothing to report; also involved in bring-up days.

XRO:
- An e-mail will be sent as preliminary tests will be done as preparation for SEPS tests next Monday. It is transparent to the machine.

LAS:
- Not present.

UNSYS:
- All good with undulators.

SPB:
- Nothing to report.

FXE:
- Nothing to add.

MID:
- All fine at MID.

HED:
- All fine at HED.

SCS:
- Today bring up days happening.

SQS:
- Nothing to report.

SXP:
- Not present.
  531   17 Jul 2024, 09:50 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 17.07.2024
General Announcement:
- Martin Doering informs today an e-mail will be sent to groups asking for tasks that are cancelled or postponed. The feedback will be required until mid of next week.
- A. Galler informs on a report for non-correct bunch arrival monitors at the instruments. It is requested to instruments to get information on this topic and bring back to XO.
- User Operation Meeting starts next Friday 19.07.

CTRL:
- Nothing to report.

DA:
- Not present.

EEE:
- Nothing to report.

VAC:
- Not present.

XPD:
- Gotthard-II in XTD6 Hirex: today the power supply will be checked and by end of the day info to XO/PRC will be done.

DET:
- SPB/SFX an issue with Jungfrau-4M high voltage power supply system happen and is broken needing a fix.
- Hirex/Gotthard-II the tests with beam is prioritized on Monday/Tuesday next week.

ITDM: 
- Nothing to report.

XRO:
- On the weekend it starts the technical ramp-up of SA3 and Monday/Tuesday the SA2 and SA1;
- On Monday the SEPS interlock tests are happening and hutches will be closed.

LAS:
- Nothing to report.
- Bunch pattern server issue last week: fix was provided. No more info on the effects of it on LAS preparations.

UNSYS:
- Issue with SA3/cell18 undulator did not move and hit the limit. Under investigation.

SPB:
- Nothing to add to the Jungfrau issue.

FXE:
- Nothing to report.

MID:
- Issue with vacuum system at MID - failed yesterday twice.

HED:
- Nothing to report.

SCS:
- Yesterday problem with mechanics in tunnel; will need PLC team; Leandro Z. informs is under investigation.

SQS:
- Nothing to report.

SXP:
- Not present.
  536   05 Aug 2024, 09:41 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 05.08.2024
General Announcement:
-	

CTRL:
- Nothing to report.

DA:
- Announcement: tomorrow afternoon a maintenance on online and offline calibration will take place causing a 20min downtime.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- Nothing to report.

DET:
- Nothing to report.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- Nothing to report.

UNSYS:
- Nothing to report.
- Suren K. questions SA3 instruments on the vertical polarization setup done last Saturday. 
Laurent M. and Manuel I. say that beam condition with polarized light was fine but they did not yet performed scans. Shifts in beam positions were seen but not understood. 

SPB:
- Nothing to report.

FXE:
- Tuning for SA2 and SA3 influenced FXE data collection, as it was not aware of tuning activities.

MID:
- All fine at MID.

HED:
- All good at HED.

SCS:
- Not using the shift today - done with X-ray commissioning and prioritizing the laser work.
- Changing number of pulses seemed to affect FXE for a second or so. Agreed to inform FXE when wanted to change pulses.
- XGM position was behaving weirdly. Drifts of the beam in the horizontal was seem by order of 1mm.

SQS:
- Nothing to report.

SXP:
- Will use the beam today instead of SCS.
  537   07 Aug 2024, 09:38 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 07.08.2024
General Announcement:
- A. Galler informs to SQS that the vertical polarization operation is planned for Thursday starting tuning in the afternoon 15:00. Please SQS inform BKR if tuning can start earlier.

CTRL:
- Nothing to report.

DA:
- Nothing to report.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- Nothing to report.

DET:
- Nothing to report.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- SA2 and SA3 with normal operating parameters.
- SA1 get extra time to work today from SPB/SFX.

UNSYS:
- Nothing to report.

SPB:
- Nothing to report.

FXE:
- Not present.

MID:
- Nothing to report; HXRSS is planned for this week. 

HED:
- Not present.

SCS:
- Yesterday and Monday problems with Interlocks but were fixed.

SQS:
- Nothing to report.

SXP:
- Nothing to report; it was useful to use the beam on Monday.
  538   12 Aug 2024, 09:44 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 12.08.2024
General Announcement:
- A power glitch happened on the weekend but had no effects on the machine. So far XO is not made aware of effects at XFEL. Please let XO know if you were affected.

CTRL:
- Nothing to report.

DA:
- Unfortunately the CAL noticed the past week that issues related to the upgrades in the maintenance period, which result in disturbances across most instruments with beam last week. 
A new version of the online correction software meant to be installed then and tested during the bring-up days, but the old version ended up still running at most of them.
When bug fixes found since then were meant to be distributed in the past two weeks as we commonly do, this inadvertently also switched these to the new version, the last time on last Tuesday. 
This was particularly aggravated by the fact the new version has some minor naming and UX changes, which the instruments had to adapt to now during operation.
Most issues reported through the DOC have been hot-fixed already, with more fixes prepared over the weekend. The DOC will contact instruments to apply these as needed.

EEE:
- FXE mono mitigation is in place and working.

VAC:
- Nothing to report.

XPD:
- Remarks on SA1 HIREX interlocks over the weekend has been addressed. Naresh K. is contact with XO, SPB/SFX and FXE.

DET:
- Nothing to be reported.

ITDM: 
- Nothing to report.

XRO:
- Not present.

LAS:
- Working on SPB side and performance improvements were done.

UNSYS:
- Everything is fine.

SPB:
- Calibration issues as mentioned by DA. It is an operational risk for AGIPD until it is clear what happens with the calibration/errors.

FXE:
- Nothing to report apart of the Mono.

MID:
- All fine at MID. Calibration is not a big problem for MID as they do not use AGIPD.

HED:
- In contact with DOC to reset some ADCs.

SCS:
- Not present.

SQS:
- Not present.

SXP:
- Nothing to report.
  539   14 Aug 2024, 09:44 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 14.08.2024
General Announcement:
- This morning difficulties to switch to SA2 9keV SASE happen but right now it is working for delivery to HED.
- Eric Boyd informs D3 would like to access an optical hutch to test insert for BTM on next Tuesday. An e-mail will be sent to xo-info mailing list asking for an instrument to open one optics hutch. 

CTRL:
- Nothing to report.

DA:
- Nothing to report.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- Nothing to report.

DET:
- Issue with chiller at SPB/SFX for AGIPD which does not maintain temperature. Investigation shows it is a cooling water flow so T is not stable; 
Issue started after LOOP5 upgrade but seems to be coincidence. Solution still pending, maybe an installation of a new pumping system will happen.

ITDM: 
- Not present.

XRO:
- Not present.

LAS:
- Nothing to report.

UNSYS:
- Everything is fine; HXRSS 2nd crystal is now retracted in parking position.

SPB:
- Nothing apart of the AGIPD issue.

FXE:
- Nothing to report.

MID:
- Nothing to report.

HED:
- Not present.

SCS:
- Not present.

SQS:
- Not present.

SXP:
- Not present.
  540   19 Aug 2024, 09:41 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 19.08.2024
General Announcement:
- As DRC, Steffen Hauf reminds that if support from DA groups is needed, please request as soon as it is needed; Second: please instruments check if the Zoom is installed and running in the control rooms.

CTRL:
- Announcement: tomorrow around 13:00 a deploy of the new tag of Karabo is to happen in order to fix a bug on missing some devices in the topology. 
Downtime is 10-15 minutes and GUI clients must be restarted. E-mail to xo-info will be sent.

DA:
- Nothing to report.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- Nothing to report.

DET:
- Not present.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- Last Wednesday all PP-lasers went down: investigation from Sync group does not show missing trigger; EEE also did not find anything; still on investigation for the root cause.

UNSYS:
- SA3 cell 24 problem: first Apple-X is not reachable. A ZZ is to happen tomorrow Tuesday in the morning to investigate. Apple-X is planned to be used by SQS and SXP this week.

SPB:
- Chiller issue not yet solved.

FXE:
- Nothing to report.

MID:
- Nothing to report.

HED:
- Not present.

SCS:
- Not present.

SQS:
- Not present.

SXP:
- Not present.
  541   21 Aug 2024, 09:46 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 21.08.2024
General Announcement:
- Next Monday 26.08 the beam delivery will be interrupted from 13:30 to 18:30 due to the SRI visit at EuXFEL. These hours are compensated by extending the beam delivery on Tuesday from 7:00AM up to 12:00.
As DRC, Wajid E. informs the DOC shifts are extended to cover the period of delivery on Tuesday morning.

CTRL:
- GUI server was updated with success.

DA:
- Nothing to report.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- Nothing to report.

DET:
- SPB AGIPD: Julabo chiller still not fixed and work together with TS for an asap solution. Right now AGIPD is not operational. The new pump is yet to arrive.

ITDM: 
- Nothing to report.

XRO:
- No news to report.

LAS:
- AMPHOS service started in SA1 for next week or so.
- SA3-PPL work ongoing.
- SA2-PPL in delivery.
- Reasons why the PP-lasers went down last Wednesday under discussion. Right now it seems to be a singular event.

UNSYS:
- Everything fine; ZZ was successful and the Circular polarization is already working for delivery to SQS.

SPB:
- Nothing to add besides the AGIPD.

FXE:
- Nothing o report.

MID:
- All fine at MID.

HED:
- Not present.

SCS:
- Not present.

SQS:
- Not present.

SXP:
- Not present.
  543   28 Aug 2024, 09:52 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 28.08.2024
General Announcement:
- Communications Group thanks all people involved on the SRI visit. The extension of the beam delivery also worked nicely to instruments.
- As PRC, A. Galler says so far there is nothing to report or discuss for the current week.
- For next Friday the UOM will have presentations from the instruments (on stability) and from the FD activities.

CTRL:
- Nothing to report.

DA:
- All fine with DA.

EEE:
- Not present.

VAC:
- Not present.

XPD:
- No issues; preparing for the FD studies;
- ZZ in XTD2 on Friday to repair camera needed for XFLO.

DET:
- MID AGIPD HV issue on weekend: no power glitch happened that was registered from Desy systems; 
still not understood the reason but likely a local power glitch (small voltage drop (peak) was seen) and will be further tracked. 

ITDM: 
- E-mail sent yesterday for general configuration on displays.

XRO:
- Not present.

LAS:
- SA1-PPL Amphos service ongoing;
- SA3-PPL changing repetition rate for next experiments.

UNSYS:
- Everything is fine.

SPB:
- Nothing to report.
- Issues with trigger distribution systems yesterday happened but was fixed on the fly.

FXE:
- Nothing to report.

MID:
- Nothing to report.

HED:
- Nothing to report.

SCS:
- Not present.

SQS:
- Not present.

SXP:
- Not present.
  544   02 Sep 2024, 09:53 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 02.09.2024
General Announcement:
-	 

CTRL:
- Today an IT update on project database at 13:00: 15min service is not available (not able to open them). Reminder will be sent.

DA:
- Note after meeting: Nothing to report.

EEE:
- Nothing to report.

VAC:
- Pressure spike in SA1 vacuum system that tripped interlock but it was quickly recovery on Thursday.

XPD:
- Nothing to report.

DET:
- Issue with Julabo chiller at AGIPD still persists as test last week did not succeed.

ITDM: 
- Nothing apart of the mentioned CTRL report.

XRO:
- Vacuum spike was caused by the one motor at M1/SA1 being loose; Incident with InGa spillage in mirror chamber as a result; 
- M1 Rz motor was reconnected and mirror was put in place again but now should not be moved anymore and it is interlocked. 
- On Saturday beam was found back at SPB/SFX (saved trajectory at one photon energy; for others have to be checked - please do not rely on previously saved positions).
- Beam was not yet found at FXE – M3 reflection at the M3 Pop-in still seen but not further downstream.
- In case of need please do not hesitate in contacting XRO and Antje Trapp for help.

LAS:
- SA1 PP-laser NOPA alignment starting today for delivery tomorrow as AMPHOS service is done.

UNSYS:
- Quad mover stuck in cell7/SA3; needs ZZ.
- Apple-X activities during FD week had re-alignment with beam; found issue with one CAM mover in cell#25. 

SPB:
- Chiller for AGIPD: tests did not get enough temperature.

FXE:
- Nothing to report.

MID:
- All fine at SA2.

HED:
- Getting ready to take beam.

SCS:
- Nothing to report.

SQS:
- Not present.

SXP:
- Not present.
  545   04 Sep 2024, 09:40 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 04.09.2024
General Announcement:
- Machine tuning last two days was hindered as a power supply for a camera in injector laser had to be exchanged. As consequence, the camera moved and had to be re-aligned costing time. 
So far, they manage to tune satisfactory and beam is delivered to instruments since 7AM.

CTRL:
- Nothing to report.

DA:
- Nothing to report.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- Not present.

DET:
- Nothing new on the AGIPD issue.

ITDM: 
- Nothing to report.

XRO:
- No deterioration of M1/SA1 since weekend.

LAS:
- PP-L SA1 AMPHOS service finished and in delivery to instruments.

UNSYS:
- Issue of last Monday is fixed.

SPB:
- Aligned beam with FXE together; beam is found at SPB/SFX and FXE.

FXE:
- Nothing to report.

MID:
- All is fine.

HED:
- Setup of beamtime going smooth; HIREX setup ongoing; tuning for HXRSS from 11AM.

SCS:
- Mechanical problem: vacuum chamber had to be vented and is now pumping down.
- Other work in parallel with samples is progressing.

SQS:
- Nothing to report.

SXP:
- Not present.
  546   09 Sep 2024, 09:38 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 09.09.2024
General Announcement:
- A. Galler informs a downtime of about 30min happened this morning in the North Branch due to a faulty vacuum controller.
- H. Sinn mentions on the beam drift in SA1: it was seen in both instruments over the weekend and is likely the comes from M1 but can be corrected by feedbacks in M2 and M3; 
drift does not slowdown and together with XRO it will be looked if corrections on M1 can be applied tomorrow.

CTRL:
- Nothing to report.

DA:
- Nothing to report.

EEE:
- A motor in FXE attenuator had an issue on Saturday; it seems issue with encoders and to be further investigated.

VAC:
- Last week was quiet;
- Issue with ion pump controller behaving strangely; to be exchanged tomorrow. System is recovered and can run until tomorrow.

XPD:
- Nothing to report.

DET:
- Nothing major to report; no news on SPB AGIPD chiller.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- Nothing to report.

UNSYS:
- Issue with cell26/SA1 showing error in gap was fixed.

SPB:
- Nothing to report.

FXE:
- Beam drift was seen at FXE; it is communicated to PRC and XRO.
- Feedbacks for M2 and M3 manage to correct the beam drift.

MID:
- Nothing to report.

HED:
- Nothing to report.

SCS:
- Not present.

SQS:
- Nothing to report.

SXP:
- Not present.
  547   11 Sep 2024, 09:50 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 11.09.2024
General Announcement:
-  Todays the machine setup is ongoing and from tomorrow it starts the beam delivery, as planned.

CTRL:
- Nothing to report.

DA:
- Nothing to report.

EEE:
- P. Gessler informs there is no DOC today as there is no beam delivery; DRC is normally reachable.

VAC:
- Yesterday ZZ to exchange preventively a pump controller was carried out successfully.

XPD:
- Nothing to report.

DET:
- Nothing to report.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.
- M. Vannoni says the SA1 drift (by M1) is being monitored and shall not be disruptive as feedback corrects it. XRO will keep an eye and assist in case of need.

LAS:
- SA3-PPL is being delivered.
- SA1-PPL being changed to THz experiment; to be ready today.
- SA2-PPL being changed to 1.1MHz, but no amplification was found; Rolled back to 188kHz to delivery to MID.
- Delay of trigger reported days ago: Desy looked into it and did not find anything specifically; Patrick G. will discuss with LAS.

UNSYS:
- Masking of undulator errors at BKR was addressed with MXL. 

SPB:
- Nothing to report.
- New Radiation constraints were issued and operation has to be with photon energies higher than 8keV.

FXE:
- This week’s nights will have operation higher than 8keV.

MID:
- Nothing to report. No limitations for photon energies on SA2 side.

HED:
- Nothing to report.

SCS:
- Detector calibration last Monday had issue with girder movement; EEE is aware and has to be working next beamtime.

SQS:
- Nothing to report.

SXP:
- Not present.
  548   16 Sep 2024, 10:03 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 16.09.2024
General Announcement:
- As PRC, Maurizio V. reports some calls over the weekend mostly for exchange of info on minor issues that were addressed

CTRL: 
- Nothing to report.

DA:
- Nothing to report.

EEE:
- Reported issue with PP-laser: P. Gessler talked to Desy and LAS, and together with Bruno found the delayed train and is under investigation. 
No guarantee it can't happen again, but it may be a one-time event. Under investigation for reason behind.

VAC:
- Nothing to report.

XPD:
- Nothing to report;

DET:
- Nothing to report.
- Marcin S. asks on a problem with MID problem getting correct gain previous; data disappeared then recovered; 
- It is not a detector it self issue; Philip S. looked this morning; DAQ being loaded and could be the cause with this particular aggregator. Ticket has been issued; aggregator was working at 8AM.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- Not present.

UNSYS:
- Nothing to report.

SPB:
- Nothing to report.

FXE:
- Nothing to report.

MID:
- Nothing to report.

HED:
- Nothing to report.

SCS:
- Nothing to report.

SQS:
- Not present.

SXP:
- Not present.
  549   18 Sep 2024, 09:51 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 18.09.2024
General Announcement:
-	 

CTRL:
- Nothing to report.

DA:
- Nothing urgent to report;
- Managed to understand the AGIPD MID issue reported last Monday: it was an one-time event; a manual shutdown of correction devices was done and cause the errors. 
Please do not try to restart manually and use the automated procedure.

EEE:
- Nothing to report.

VAC:
- Nothing to report.

XPD:
- Nothing to report.

DET:
- Nothing to report.

ITDM: 
- Nothing to report.

XRO:
- All fine.

LAS:
- Not present due to a workshop.

UNSYS:
- All good.

SPB:
- Starting with beam operation; nothing to report.

FXE:
- All fine.

MID:
- All fine.

HED:
- All fine.

SCS:
- Nothing to report.

SQS:
- Not present.

SXP:
- Not present.
  550   23 Sep 2024, 10:01 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 23.09.2024
General Announcement:
-  As DRC, Krzysztof Wrona and Monica Turcato report all is fine at DOC, no major issues and no DRC calls overnight.

CTRL:
- Nothing to report.

DA:
- Nothing to report.

EEE:
- EEE is on retreat next Wed afternoon and entire Thursday.

VAC:
- Nothing to report.

XPD:
- Nothing to report.

DET:
- Nothing to report.
- Meeting ongoing on chiller issues together with TS, SPB/SFX.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- Not present.

UNSYS:
- No news; all fine.

SPB:
- Issue with chiller is a treat to next experiments.

FXE:
- Problem with laser shutter (2-3x trigger interlock). 
- Pouneh S. asks which shutter closes: it's AMPHOS shutter.

MID:
- Nothing to report.

HED:
- Runs good with users.

SCS:
- Nothing to report.

SQS:
- Nothing to report.

SXP:
- Preparing for commissioning in cw41.
  551   25 Sep 2024, 09:57 Frederik Wolff-FabrisGeneralInformationNotes XO Integration Meeting 25.09.2024
General Announcement:
- Machine had a rough day yesterday and last night with downtimes due to problems with L-IBFB, dump communication, vacuum in A14. 
Files for beam delivery were prepared and small pointing corrections had to be done this early morning. Beam is currently in delivery mode.
- Martin Doering present the schedule on the preparation for the next Winter Maintenance Period: task list will be sent to groups on 11.10 and shall be returned to XO by end of October.

CTRL:
-  Nothing to report.

DA:
- Not present.

EEE:
- EEE reminds the group will be in a retreat today and tomorrow.

VAC:
- Issue with GATT this morning in SA3: Argon supply line shows interruption and need a ZZ to evaluate the issue.
- As PRC, Jan G. says that it is organized with BKR and SPB/SFX and ZZ can happen as soon as VAC colleagues are ready to enter tunnel.

XPD:
- Changed PES setup to run this week.

DET:
- Nothing to report.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- In theory nothing to report.
- Daniel Kane will speak to XO and LAS about THz delivery last week to FXE.

UNSYS:
- Nothing to report.

SPB:
- Water leak in top of control room today: TS is working; humidity is still high.
- Installing the new chiller and AGIPD being cooled down.

FXE:
- Nothing to add.

MID:
- All fine at MID; vacuum issues in hutch but A. Parenti is on it or already solved.

HED:
- Not present.

SCS:
- Nothing to report.

SQS:
- Nothing to report.

SXP:
- Not present.
ELOG V3.1.4-7c3fd00