308
|
17 Aug 2023, 11:07 |
Teguh Citra Asmara, Eugenio Paris | SCS | Morning Shift Summary on 16.08.2023 |
Achievements:
- Performed tr-RIXS on peak A, B, and C at 2.4 mJ/cm^2
- Performed tr-XAS on peak A at 3 fluences
- Performed tr-RIXS on peak A at 4 mJ/cm^2
Problems:
- BAM delay line compensator was not working due to incorrect macro. DOC and LM fixed the issue.
- Delay line scan of hRIXS camera was not working as it was still configured for Viking. MT fixed the issue.
- The new centroiding algorithm (provided natively by the 4137 kernel) is not consistent with integration mode. For the time being, we use an older, manually configured centroiding algorithm developed for a previous user beamtime.
- tR-XAS results show large changes, but these large changes were not reflected in tr-RIXS.
|
309
|
17 Aug 2023, 11:08 |
Teguh Citra Asmara | SCS | Afternoon shift summary on 16.08.2023 |
Achievements:
- tr-RIXS at 4 mJ/cm2 for energies A, B, C, and D (pre-edge)
- Checked and optimized FEL alignment, t0 and overlap with PP laser after reset of machine synchronization
-
Long delay scans for Peak A and C, up to 100 ps
Problems:
-
Need to reset machine synchronization by BKR
-
Camera scene got stuck, was resolved by DOC
|
138
|
16 Apr 2023, 15:35 |
Silja Schmidtchen | XRO | Shift summary |
shift summary from Saturday 15.04.2023:
Tasks:
- Calibration of Euler MDL
- Vibrometer measurements at M3 using the RY piezo
Beam was aligned to MID popin
we used values stored in MID setpoints 'B' but went there manually, using the EulerMDL
M1 - X value was corrected, as we found the center of the beam/mirror to be at 6.4mm - calculated beam angle after M1 is 2.14mrad
M2 - values slightly differ from saved setpoints but were quite well met using EulerMDL to reach the same beam position
M3 - we had to remove it a bit further from the beam, as it seemed to intercept it, when we first tried to get the beam through. This might in the end not have been necessary
End of shift:
beam aligned to MID
preabsorber in
SRA fully open |
272
|
21 Jul 2023, 20:31 |
Silja Schmidtchen | XRO | Shift Summary SA2 |
Alignment to HED: https://in.xfel.eu/elog/XRO+Beam+Commissioning/205
SA2 - divergence with various M2 bender positions HED - https://in.xfel.eu/elog/XRO+Beam+Commissioning/200
SA2 - divergence with various M2 bender positions MID - https://in.xfel.eu/elog/XRO+Beam+Commissioning/196
Issues with HED PBLM blade in SA2: https://in.xfel.eu/elog/XRO+Beam+Commissioning/195
Vobration measurements could not be done https://in.xfel.eu/elog/XRO+Beam+Commissioning/207
End of shift:
SA2 left with preAbs in
machine wanted to increase intensity |
414
|
25 Oct 2023, 15:10 |
Sergii, Teguh | SCS | Morning Shift Summary, 24.10.2023 |
Morning Shift Summary, 24.10.2023
Achievements:
- Re-aligned the beamline after maintenance
- Found time zero using SiN at 300 K
- Change the He dewar and cooled down back to 20 K
- Adjusted the AFS laser parameters to recover the proper experiment settings
- Started taking tr-RIXS with several time delay points
Problems:
- The AFS laser power is smaller than last week
Next shift plan:
- Continue taking tr-RIXS data
|
415
|
25 Oct 2023, 15:18 |
Sergii, Teguh | SCS | Morning Shift Summary, 25.10.2023 |
Morning Shift Summary, 25.10.2023
Achievements:
- Re-aligned FEL beam pointing and beamline mirrors after XGM intensity drop due to slow beam pointing drift over night.
- Continued taking momentum-dependent tr-REXS data.
Problems:
- There was slow drift of FEL beam pointing over night, causing XGM intensity to slowly drop over time.
- The slow drop of XGM intensity continues even after beamline alignment. Compared to morning, the XGM intensity has dropped by ~10%.
- It is advisable to re-check the beam pointing again some time before the night shift due to correct for this beam drift problem.
|
418
|
26 Oct 2023, 15:03 |
Sergii, Teguh | SCS | Morning shift summary, 26.10.2023 |
Morning shift summary, 26.10.2023
Achievements:
- Continued measuring tr-RIXS at different laser fluences
Problems:
- The max-jhub notebook server was very slow this morning around 9-10 h. DOC was informed, but the slowness has improved without any action from either them or our side. The reason for this slowness is still unknown, but the max-jhub server has come back to normal for now.
|
175
|
04 May 2023, 22:58 |
Sergii, Phuong | SCS | Late shift summary 04.05.2023 |
Achivements:
-Cooling down the sample. Sample is at 14K
-Taking time resolved data at 70% 800 nm, -5 ps - 65 ps
Problems
-Freezing of the transfer line while cooling. It seems the scroll pump was brocken. When we replace the pump cooling was OK. |
183
|
05 May 2023, 23:00 |
Sergii, Phuong | SCS | Late shift summary 05.05.2023 |
Achivments:
-Measure time scans with magnetic field in opposite directions
Problems
-At some point data analysis was imposible. No reseurses could be dedicated for the analysis. We switch both AMORE and offline analysis to nodes, dedicated for the proposal.
-We found very slow drift of xray intensity at XGM. It was becasue x-ray pointing was slightly changed. We restore the pointing with M2 pitch motor |
189
|
06 May 2023, 23:15 |
Sergii, Phuong | SCS | Late shift summary 06.05.2023 |
Achivments:
-Measure delay scans at two PPL fluencies on smaller grain size.
-Moved DSSC back to 1.45 m sample - detector distance
Problems
-No major problems |
193
|
07 May 2023, 23:11 |
Sergii, Phuong | SCS | Late shift summary 07.05.2023 |
Achivments:
-Move DSSC closer to the sample.
-Measure delay scans for opposite magnetic field.
Problems:
-No major problems |
62
|
01 Mar 2023, 23:31 |
Sergii, Martin | SCS | Late shift summary 01.03.2023 |
Achievments:
- Align DPS to remove clipping of X-rays
- Get better focusing of PPL in the chamber
-Coarse timing with SIGNAl of OPA
-Switch back to 3 um PPL settings
Problems
-It was hard to work with DPS without motorized stages
|
284
|
31 Jul 2023, 01:42 |
Sergii, Martin | SCS | Night shift summary 30.07.2023 |
Achivements:
-We measured vertical spot size for several VFM settings
Problems:
-We cannot focus the x-ray beam with KB. The best value what we can get is ~300 um. We checked the slits of KB. The ALAS is slightly clipped on parabolic mirror of tim ing chamber. TI is not clear if this is the reason. We cannot proceed with the program for hRIXS.
-Still no signal on APD. |
275
|
28 Jul 2023, 06:38 |
Sergii, Manuel | SCS | Shift Summary 27_07_23 night |
Achievements:
1. Beam in sample chamber, almost overlapping with ALAS
2. We saw signal on MCP and diode2
3. Sample Motors aligned close to the desired height in chamber
Problems:
1. Slow response of Screens and mirror motors, solved by restarting the Beckhoff of the mirror motors
2. Could not find signal of unfocused beam on SCS Pop-In
3. Acquiring data with the spectrometer for energy calibration does not work
4, Motor STZ of XRD does not allow halfclip of the beam.
5. No Fluorescence signal on the APD
6. In the DAQ we can not execute "assign" or "cofigure" action |
313
|
19 Aug 2023, 07:16 |
Sergii, Manuel | SCS | Noght shift sammary 18.08.2023 |
Night shift summary on 18.03.2023
- Finished XAS series at 1.5 mJ/mm² for different delays
- Performed XAS at 6 mJ/mm²
- Tested tr-RIXS signal at 1mj/mm² with 29 different delays, signal too weak to continue
- Took 5 hours of tr-RIXS signal at 1.2 mj/mm² with 29 different delays
Problems:
- Something in the cryo line froze, cleaned the line by going into the hutch and moving the needle valve a bit. This only helped short-term, as it kept freezing after short time.
- Temperature sensor at the sample stopped working, started to work again during the heating
|
398
|
20 Oct 2023, 23:22 |
Sergii, Giacomo | SCS | Late Shift Summary on 20.10.2023 |
Late shift summary 20.10.2023
Achievements
-Switched AFS to burst mode
-Characterized PPL beam size
-Found coarse timing
-Working on fine timing with TR_XAS
Problems
-SCS_XGM data recorded with some mismatch that the run could not be loaded for an offline analysis with XGM. Other channels are fine.
|
401
|
21 Oct 2023, 23:34 |
Sergii, Giacomo | SCS | Late shift summary 21.10.2023 |
Achievements:
-Collecting TR-RIXS data for different fluencies and delay range
Problems
-No major problems |
72
|
04 Mar 2023, 23:04 |
Sergii, Andreas | SCS | late shift summary |
Achievements:
- we replaced broken SMA cable, and added an angle-connector at sample holder to aid the sample rotation when moving diagnostics to the flat jet
- we double-checked coarse timing and x-ray beam size
- we found t0 on SiN
- setting up RIXS with time delay steps for the night shift program
|
73
|
05 Mar 2023, 23:04 |
Sergii, Andreas | SCS | Late shift summary 05.03.2023 |
Achievments
-RIXS scans at different delay times and x-ray energies
-Cross check fine timing
Problems
-Nozzle was frozen. Pump was in error state. |
290
|
05 Aug 2023, 23:06 |
Sergii, Andreas | SCS | Late shift summary 05.08.2023 |
Achievements:
- Find course timing with antenna
-Find find timing signla with TR_XAS on the sample
-Measure XAS with laser ON and OFF to find optimal conditions for TR study
-Measure TR_XAS at low T
Problems:
-temperature went up and the cooling was not responing to the change of needle valve. When we tweak a bit transfer line needle valve cooling starts again. |