Group Selection Page HELP DOC Controls Group Data Analysis Group ITDM WP76 DET Vacuum XRO EEE WP78 WP74 FXE SCS SPB MID HED SQS SXP Sample Environment Photon Commissioning Team Operation PSPO XO TS
OPERATION-2024 OPERATION-2023 OPERATION-2022 OPERATION-2021 OPERATION-2020 OPERATION-2019 SASE1-2018 SASE1-2017 Experiment data
  OPERATION-2024 logbook, Contact: F.Wolff-Fabris, A.Galler, H.Sinn, Page 5 of 11  Not logged in ELOG logo
ID Datedown Author Group Subject Text Attachments
  128   22 Jul 2024, 15:27 Antje TrappXROSASE3 end of shift summarythis morning, ZZ was done together with
Sylvia Huynh (EEE) to solve softmono pre-mirror
motor issue https://redmine.xfel.eu/issues/177392
  
  129   22 Jul 2024, 15:20 Antje TrappXROSASE2 end of shift summaryBeam is now aligned back to HED for hand-over
to Naresh (see picture)

points achieved:
 HED_beam__2024-07-22_15-19-15.png 
  127   18 Jun 2024, 13:03 Kelin TascaXROCompensation of M2 RY motor for the case of Piezo offWe plan to put the piezos of M2 off, in
the (unprobable) case that this is the reason
of the "jumps" in SASE3 trajectory.
 Screenshot_from_2024-06-18_13-16-14.pngScreenshot_from_2024-06-18_13-18-15.pngScreenshot_from_2024-06-18_13-20-06.png 
  126   14 Jun 2024, 01:53 Jörg HallmannMIDShift summarycontinue with Tempus tests
continue with PAM commissioning (first
results of the working device at MID)
  
  125   13 Jun 2024, 01:46 Jörg HallmannMIDShift summaryalignment of the instrument including collimation
and beam shaping
test of the tempus detector using
  
  124   11 Jun 2024, 00:43 Abhisakh SarmaSPBShift summary**X-ray delivery**


7.0 keV, up to 202 pulses
at 564 kHz, 1.0 mJ.


**Optical
  
  123   09 Jun 2024, 22:45 Chan KimSPBShift summaryX-ray delivery


7.0 keV, up to 202 pulses
at 564 kHz, 1.0 mJ.


Optical
  
  122   09 Jun 2024, 22:21 Giuseppe MercurioSCSShift summaryLate Shift summary

Achievements:
- recovered the beam overlap
  
  121   08 Jun 2024, 23:20 Abhisakh SarmaSPBShift summaryX-ray delivery
- 7.0 keV, up to 202 pulses at 564
kHz, 1.0 mJ.
  
  120   08 Jun 2024, 15:21 Natalia GerasimovaSCSShift summary
Morning
shift on 08.06.2024 (Natalia, Teguh, Yi Ping)

Achievements:


Focus the KB to ca. 40
  
  119   07 Jun 2024, 23:12 Chan KimSPBShift summaryX-ray delivery
- 7.0 keV, up to 202 pulses at 564
kHz, 1.0 mJ.
  
  118   07 Jun 2024, 15:19 Giuseppe MercurioSCSShift summary
Morning
Shift Summary for 07.06.2024 (Teguh, Natalia)

Achievements:


Aligned the beamline to
  
  117   05 Jun 2024, 23:22 Romain LetrunSPBShift summaryX-ray
delivery


7.0 keV, up to 202 pulses
  
  116   04 Jun 2024, 23:38 Romain LetrunSPBShift summaryX-ray
delivery


7.0 keV, up to 202 pulses
  
  115   27 May 2024, 23:33 Romain LetrunSPBShift summaryX-ray
delivery


6.0 keV, up to 202 pulses
  
  114   27 May 2024, 06:41 Konopkova ZuzanaHEDShift summarybeam parameters: 2 colors
at around 6.5 keV, 1 pulse

achievements: 
  
  113   26 May 2024, 23:23 Romain LetrunSPBShift summaryX-ray delivery


6.0 keV, up to 202 pulses
at 564 kHz, 1.8-1.9 mJ.
Stable
  
  112   26 May 2024, 21:56 Thomas BaumannSQSStability IssueWe asked the machine for two color mode
in the morning. Tuning gave good results
at first (1.6mJ second color, 100uJ first
  
  111   26 May 2024, 00:23 Romain LetrunSPBShift summaryX-ray delivery


6.0 keV, up to 202 pulses
at 564 kHz and 101 at 282 kHz, 0.8-1.6 mJ
Low
  
  110   25 May 2024, 02:38 Rebecca BollSQSIssueToday in the afternoon, SASE1 was tuned
(a description of the activities in att 4).
We now realize that this has in some form
 Run_177_vs_247.pngScreenshot_from_2024-05-25_00-44-46.pngScreenshot_from_2024-05-25_01-03-29.pngScreenshot_from_2024-05-25_01-36-54.png 
ELOG V3.1.4-7c3fd00