Entry   Shift summary, posted by Wonhyuk Jo on 13 Sep 2024, 02:16 
- DAQ was crashed after taking darks of AGIPD. It was solved by DOC and OCD.

- Laser could not switched from optical to RF lock. Solved by OCD (using doocs).
- Energy scan was attempted, which was not successful. 
Entry   Shift end, posted by Adam Round on 12 Sep 2024, 23:48 
X-ray delivery

8.951 keV, 1.6 mJ

Achievements/Observations
Entry   Shift summary, posted by Romain Letrun on 10 Sep 2024, 07:26 
X-ray delivery


12.8 keV, 1-20 pulses at 47 kHz, 500-700 uJ.
Pulse energy constantly decaying since ~3:00.


Achievements/Observations


Continuous SFX data collection since 00:10.


Issues
Entry   Issue, posted by Peter Zalden on 09 Sep 2024, 23:19 2024-09-09-231922_609331430_exflqr51474.png
Finally, the drift velocity of the pointing reduced approx a factor of 2 as compared to yesterday, see attached. Possibly it will still converge...
Entry   Shift summary, posted by Romain Letrun on 09 Sep 2024, 06:52 
X-ray delivery


12.8 keV, 1 pulse, ~0.7 mJ


Achievements/Observations


Except for some downtime due to beam down, majority of the time was for data collection
6 windows of a chip collected, with
Entry   Issue, posted by Peter Zalden on 08 Sep 2024, 20:30 2024-09-08-194936_755701995_exflqr51474.png
We observe a continuous horizontal beam drift in SA1 after the M1 incident. It seems not to converge, so one can wonder where this will go....

Attached screenshot shows the M2 piezo actuator RY that keeps the beam at the same position on the M3 PBLM. These are about 130 m apart, The
drift is 1V/12 hours. 0.01V corresponds to a beam motion by 35 um. So the drift velocity is 0.3 mm/hour. In the past days this had at least once lead to
Entry   Shift summary, posted by Tokushi Sato on 08 Sep 2024, 06:44 
X-ray delivery

12.8 keV, ~0.8 mJ

Achievements/Observations
Entry   M1 Rz damaged - DO NOT MOVE!!!, posted by Antje Trapp on 30 Aug 2024, 13:02 6x
What has happened:
During euler motion calibration of M1, we were driving the vertical motors by a few mm back and forth. At some point, the Rz motor went into error,
as we attempted to go further in negative direction. Resetting the axis several times did not solve the problem. The vertical motors were then moved to
Entry   Shift summary, posted by Chan Kim on 27 Aug 2024, 12:17 
X-ray delivery


12.78 keV, ~1.3 mJ


Optical laser delivery


800 nm laser for jet visualization


Achievements/Observations
Entry   Shift summary, posted by Tokushi Sato on 26 Aug 2024, 23:05 
X-ray delivery

-12.40 - 12.82 keV, ~1.3 mJ

Optical laser delivery
Entry   Shift summary, posted by Tokushi Sato on 25 Aug 2024, 22:37 
X-ray delivery

-12.40 - 12.82 keV, XDT9 XGM ~0.85 mJ, 3 hours interruption by vacuum issue on XTD9

Optical laser delivery
Entry   Shift summary, posted by Chan Kim on 24 Aug 2024, 23:09 
X-ray delivery

-12.40 - 12.82 keV, XDT9 XGM ~0.81 mJ@ end of shift

Optical laser delivery
Entry   Shift summary, posted by Peter Zalden on 23 Aug 2024, 08:48 
Used 9.4 keV with 94 kHz wed and thu nights. Received approx. 0.9 mJ with large fluctuations in pulse energy, however acceptable for the tasks below.

Achievements:


X-ray optics and goniometer aligned for next user experiment 5725
Transmission through Mono #2 recovered and calibrated to
Entry   Shift summary, posted by Raphael de Wijn on 22 Aug 2024, 23:15 
X-ray delivery

12.40 - 12.82 keV, ~1.1 mJ

Optical laser delivery
Entry   Shift summary, posted by Raphael de Wijn on 21 Aug 2024, 23:34 
X-ray delivery

12.40 - 12.82 keV, ~1.1 mJ

Optical laser delivery
Entry   Shift summary, posted by Wonhyuk Jo on 13 Aug 2024, 02:04 
Found the interference fringe at Suna microscope with Zyla cam from MID split-and-delay line. 
The fringe patterns were recorded as a function of delay controlled by the upper branch motor position. 
Obtained the interference fringe patterns with two pulses with different repetition rate of machine. 
Entry   Shift summary, posted by Raphael de Wijn on 12 Aug 2024, 23:47 

X-ray delivery

11.56 keV, 202 pulses @0.5 MHz, ~0.9 mJ, stable delivery

Optical laser delivery
Entry   Shift summary, posted by Wonhyuk Jo on 12 Aug 2024, 02:07 
Found spatial overlap at Suna microscope with Zyla cam.
The splitting ratio was obtained about 1:1. 
The spatial jittering from upper and lower branch were investigated.
Entry   Shift summary, posted by Raphael de Wijn on 11 Aug 2024, 23:07 
X-ray delivery

11.56 keV 202 pulses @0.5 MHz, ~1.0 mJ

some downtime due to fire alarm in the tunnel
Entry   Shift summary, posted by Romain Letrun on 11 Aug 2024, 14:33 
Summary 06.08 - 10.08

X-ray delivery


9.3 keV, 1-352 pulses @ 1.13 MHz and 564 kHz, 1.4-1.8 mJ
11.56 keV 1-352