Found the interference fringe at Suna microscope with Zyla cam from MID split-and-delay line.
The fringe patterns were recorded as a function of delay controlled by the upper branch motor position.
Obtained the interference fringe patterns with two pulses with different repetition rate of machine.
BKR provided the two color HXRSS seperated by a few eV, and SDL was aligned accordingly.
The fringe patterns were recorded as a function of delay with two X-ray photon energies. |