Entry   Shift summary, posted by Felix Brausse on 26 Aug 2023, 02:07 

Shift summary the 25th of Aug


Found laser and X-ray spatiotemporal overlap with Bi diffraction peak
Found a diffraction peak from STO nano particles

X-ray
dose test is ongoing
Entry   Strange pulse behavior upstream XGM, posted by Faisal Hammad Mekky Koua on 17 Jun 2023, 07:41 Screenshot_from_2023-06-17_07-40-49.png
- Pulse intensity decreases drastically at XTD2 across the train

- the visualisation of our beam therfore needs to be compensated adjusting transmission

- beam shape and uniformity is different than previous days and it is unclear how much of this is related to real changes in the beam or an effect
Entry   Day shift summary, posted by Erik Brambrink on 19 Feb 2023, 08:06 
19 Feb 2023, 08:08 Hand over from night shift

Added polarizer in the PAM beam in the optics hutch, reequilibrated reference arm of PAM

19 Feb 2023, 08:09 Darks taken for JF 1 and 2
Entry   Shift summary, posted by Erik Brambrink on 08 Sep 2023, 06:22 

Improved the alignment procedure:

Using the pin to make sure of the spatial overlap
SAXS signal is used to make sure
the pin is well centered on the X-ray beam path
YAG is only used in combination with ILM to fix with ~5 um precision the height of the beam
(moving CRLs on laser focus) and the temporal overlap.


Entry   Shift summary, posted by Erik Brambrink on 09 Sep 2023, 07:00 

Data taken from 11 to cryo failure
Beam conditions stable
Timing scan for different energy
Operation stopped
after cryo failure
Cryo jet was heated up then
Improvements of optical diagnostics (far field monitor)
Entry   SASE 3 background heavily impacts our focus, posted by Diogo Filipe Monrroy Vilan e Melo on 25 Oct 2023, 02:43 Screenshot_from_2023-10-25_02-21-29.pngScreenshot_from_2023-10-25_02-36-16.pngScreenshot_from_2023-10-25_02-37-38.pngScreenshot_from_2023-10-25_02-42-21.png
Attch 1: We were having trouble focusing at IRU chamber. After multiple attempts the best we could achieve was 2.9-3.1 um beam.

Attch 2: We then wanted to test if this was caused by the SASE 3 background, after them changing from >350 pulses to 1, we saw an instant
improvement of ~0.5um down to 2.3 um beamsize.
Entry   Shift Summary, posted by Diogo Filipe Monrroy Vilan e Melo on 25 Oct 2023, 06:02 
Staff: DM, CK, KK

X-ray delivery


7.8keV, 2.4mj, stable delivery, homogeneos intra train energy most of the time.
SASE 3 background


Optical
Entry   Shift summary 25.10.2023, posted by Diogo Filipe Monrroy Vilan e Melo on 26 Oct 2023, 06:48 
Staff: DM, CK, KK, JB, SR (SEC), LW (Uppsala university), MM (GU)

X-ray delivery


7.8keV, 2.4mj, stable delivery, homogeneos intra train energy most of the time.


Optical laser delivery
Entry   Issue, posted by Chan Kim on 02 Feb 2023, 06:37 Screenshot_from_2023-02-02_06-09-52.pngScreenshot_from_2023-02-02_06-11-30.pngScreenshot_from_2023-02-02_06-17-24.pngScreenshot_from_2023-02-02_06-30-00.pngScreenshot_from_2023-02-02_06-31-44.png
SPB_IRU_DPA/MOTOR issue

X stage looks okay, but Y, AX, and AY values have been changed by 2-3mm. (see attachment 1 and 2)

 
Entry   Shift summary, posted by Chan Kim on 16 Feb 2023, 07:17 
Shift summary 15.2.2023 (Wednesday)

X-ray delivery


9.3 keV, 1-200 pulses, 1.0 mJ, pulse energy fluctuation due to SA3 tunning & special operation mode (SCS)


Optical
Entry   Shift summary, posted by Chan Kim on 16 Feb 2023, 23:15 
X-ray delivery


9.3 keV, 1-120 pulses


Optical laser delivery


No Optical Laser


Achievements/Observations
Entry   Shift summary, posted by Chan Kim on 27 Apr 2023, 00:07 
SPB/SFX User Proposal 3333 Shift 2 Summary

X-ray delivery



9.3 keV, 1.7 mJ, 202 pulses @ 564 kHz
Entry   Shift summary, posted by Chan Kim on 10 Jun 2023, 06:55 
X-ray delivery


12.42 keV, 0.8 mJ/pulse, stable delivery


Optical laser delivery


none


Achievements/Observations
Entry   Shift summary, posted by Chan Kim on 11 Jun 2023, 07:28 
X-ray delivery


12.42 keV, 0.65 mJ/pulse, low pulse energy but mostly stable delivery


Optical laser delivery


none


Achievements/Observations
Entry   Shift summary, posted by Chan Kim on 12 Jun 2023, 07:16 
X-ray delivery


12.42 keV, stable delivery with slightly less than 1.0 mJ/pulse (~0.95 mJ/pulse)


Optical laser delivery


none


Achievements/Observations
Entry   Issue, posted by Chan Kim on 15 Sep 2023, 14:54 Screenshot_from_2023-09-15_14-51-56.pngScreenshot_from_2023-09-15_15-06-49.png
Vacuum issue at XTD2 tunnel which might be triggered by SA1_XTD2_ATT Arm5 (1.2mm thick CVD diamond)

It happened once again at around 3pm.
Entry   Shift summary, posted by Chan Kim on 13 Oct 2023, 07:06 
X-ray delivery


7.8 keV, up to 260 pulses at 1.1MHz, >4 mJ


Optical laser delivery


PP laser was down since 00:48.


Achievements/Observations
Entry   Shift summary, posted by Chan Kim on 14 Oct 2023, 04:04 
X-ray delivery


7.8 keV, up to 260 pulses at 1.1MHz, ~3 mJ


Optical laser delivery


PP laser, stable delivery


Achievements/Observations
Entry   Issue, posted by Chan Kim on 25 Oct 2023, 04:48 Screenshot_from_2023-10-25_02-37-38.pngScreenshot_from_2023-10-25_02-42-21.pngScreenshot_from_2023-10-25_02-35-35.pngScreenshot_from_2023-10-25_02-36-16.png
SA3 background is very strong and it affects our NKB (nano KB, Ru coating) focus.

 

Attachment 1: optimized NKB focus with 1 pulse @SA3
Entry   other, posted by Chan Kim on 25 Oct 2023, 06:02 Screenshot_from_2023-10-25_05-27-43.pngScreenshot_from_2023-10-25_05-27-13.png
Issue solved (elog:410) after changing NKB mirror coating to B4C.

 
ELOG V3.1.4-7c3fd00