Entry   Shift end, posted by Adam Round on 18 Jun 2023, 07:31 
posting for 17th June

Staff: AR, AS, FK, HH, JB, KK, DZ, MK

X-ray delivery
Entry   Shift end, posted by Adam Round on 29 Jul 2023, 23:46 
X-ray delivery


12.4 keV, up tp 352 pulses but the intensity drop across the train was too dramatic to use. reasonably stable delivery with 202 pulses.


Optical
laser delivery
Entry   Shift end, posted by Adam Round on 23 Sep 2023, 07:04 
Staff:JK, RDW, AR

X-ray delivery


7 keV 202 pulses 1.7mJ stabel across train and throughout the shift


Optical laser delivery
Entry   Shift end, posted by Adam Round on 21 Nov 2023, 23:29 
Staff: AR, MS, DM, RL, RdW

X-ray delivery


16.9 keV, up to 30 pulses and 1.1 MHz for alignment, 1 pulse for data collection
stable delivery


Optical
Entry   Shift end, posted by Adam Round on 23 Nov 2023, 23:12 
Staff: AR, MS, DM, KK, RL, RdW

X-ray delivery


16.9 keV, up to 30 pulses and 1.1 MHz for alignment, 1 pulse for data collection
900 uJ
Beam down around 1h


Optical
Entry   Shift summary, posted by Adam Round on 26 Nov 2023, 23:26 
X-ray delivery


16.9 keV, up to 30 pulses and 1.1 MHz for alignment, 1 pulse for data collection
800 uJ
Beam pointing and corrected
with M2 Ry piezo stepping optimizing scatering intensity seen on JF4M


Optical laser delivery
Entry   Taking the beam , posted by Abhisakh Sarma on 13 Jun 2023, 06:49 Screenshot_from_2023-06-13_06-57-01.png
BKR changed the beam energy from 15 keV to 12.4 keV

Energy 12.4 keV

Repeatation rate 1.1 MHz
Entry   Status, posted by Abhisakh Sarma on 16 Jun 2023, 11:42 Screenshot_from_2023-06-16_11-41-39.png
Beam is back at around 11:30 pm

We lost 1 hr 30 min of beam time.(it was promised to get back at around 10:00 am)

If we want to change the pulse number then we need to call BKR.
Entry   Shift summary, posted by Abhisakh Sarma on 11 Oct 2023, 06:22 
X-ray delivery


7.8 keV, up to 30 pulses at 94 kHz, 3 mJ


Optical laser delivery


No laser


Achievements/Observations