ID |
Date |
Author |
Location |
Severity |
Subject |
97
|
04 Apr 2017, 15:11 |
Tobias Haas | General | Information | Access to XTD2 |
MPS informed me that they hit some problems and that they still need 30 mins to 1 h until we can go to XTD. |
96
|
04 Apr 2017, 12:43 |
Alessandro Silenzi | General | Information | Temperatures from EPS loop |
Alessandro Silenzi wrote:
|
This is the list of data coming directly from the PLC via its TCP client connected to the EPS PLC.
Format:
deviceName temperature status errorCode
XTD2
==================================================
SA1_XS3_SHUT/TSENS/T1 0.4000000059604645 0xa020 0x0
SA1_XS3_SHUT/TSENS/T2 0.4000000059604645 0xa020 0x0
SA1_XS3_SHUT/TSENS/T3 0.4000000059604645 0xa020 0x0
SA1_XS3_SHUT/TSENS/T4 0.4000000059604645 0xa020 0x0
SA1_XTD2_ABS/TSENS/T1 0.0 0x20 0x0
SA1_XTD2_ABS/TSENS/T2 0.0 0x20 0x0
SA1_XTD2_ATT/TSENS/A1 30.739999771118164 0x20 0x0
SA1_XTD2_ATT/TSENS/A2 1372.0 0x15020 0x0
SA1_XTD2_ATT/TSENS/A3 30.380002975463867 0x20 0x0
SA1_XTD2_ATT/TSENS/A4 31.05000114440918 0x20 0x0
SA1_XTD2_ATT/TSENS/A6 31.130002975463867 0x20 0x0
SA1_XTD2_ATT/TSENS/A7 30.78000259399414 0x20 0x0
SA1_XTD2_ATT/TSENS/A8 30.98000144958496 0x20 0x0
SA1_XTD2_ATT/TSENS/A9 33.5 0x20 0x0
SA1_XTD2_COLA/TSENS/T1 0.0 0x1020 0x0
SA1_XTD2_COLA/TSENS/T2 0.0 0x1020 0x0
SA1_XTD2_COLB/TSENS/T1 0.0 0x20 0x0
SA1_XTD2_COLB/TSENS/T2 0.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_10_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_10_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_1_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_1_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_2_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_2_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_3_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_3_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_4_T1 33.60000228881836 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_4_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_5_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_5_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_6_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_6_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_7_T1 33.60000228881836 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_7_T2 33.5 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_8_T1 33.60000228881836 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_8_T2 33.5 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_9_T1 33.60000228881836 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_9_T2 33.5 0x1020 0x0
SA1_XTD2_DPS1/TSENS/FLOW 2.0300002098083496 0x20 0x0
SA1_XTD2_DPS1/TSENS/RETURN1 33.5 0x20 0x0
SA1_XTD2_DPS1/TSENS/RETURN2 2.0200002193450928 0x20 0x0
SA1_XTD2_DPS3/TSENS/FLOW 33.5 0x20 0x0
SA1_XTD2_DPS3/TSENS/RETURN1 4.160000324249268 0x20 0x0
SA1_XTD2_DPS3/TSENS/RETURN2 4.420000076293945 0x20 0x0
SA1_XTD2_PBLM/TSENS/BLADE_LEFT 32.900001525878906 0x20 0x0
SA1_XTD2_PBLM/TSENS/BLADE_RIGHT 33.5 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_BOTTOM_B4C 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_BOTTOM_W 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_LEFT_B4C 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_LEFT_W 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_RIGHT_B4C 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_RIGHT_W 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_TOP_B4C 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_TOP_W 0.0 0x20 0x0
XTD9
============================================================
SA1_XTD9_PBLM/TSENS/BLADE_LEFT 24.31999969482422 0x20 0x0
SA1_XTD9_PBLM/TSENS/BLADE_RIGHT 24.810001373291016 0x20 0x0
SPB_XTD9_COLB/TSENS/T1 0.0 0x20 0x0
SPB_XTD9_COLB/TSENS/T2 0.0 0x1020 0x0
SPB_XTD9_DPS1/TSENS/FLOW 33.5 0x1020 0x0
SPB_XTD9_DPS1/TSENS/RETURN1 85.0 0x1020 0x0
SPB_XTD9_DPS1/TSENS/RETURN2 85.0 0x1020 0x0
SPB_XTD9_DPS2/TSENS/FLOW 85.0 0x1020 0x0
SPB_XTD9_DPS2/TSENS/RETURN1 85.0 0x1020 0x0
SPB_XTD9_DPS2/TSENS/RETURN2 85.0 0x1020 0x0
SPB_XTD9_PBLM/TSENS/BLADE_BOTTOM 23.05000114440918 0x20 0x0
SPB_XTD9_PBLM/TSENS/BLADE_LEFT 22.860000610351562 0x20 0x0
SPB_XTD9_PBLM/TSENS/BLADE_RIGHT 23.05000114440918 0x20 0x0
SPB_XTD9_PBLM/TSENS/BLADE_TOP 23.05000114440918 0x20 0x0
SPB_XTD9_SHUT/TSENS/T1 0.0 0x1020 0x0
SPB_XTD9_SHUT/TSENS/T2 0.0 0x1020 0x0
SPB_XTD9_SHUT/TSENS/T3 0.0 0x1020 0x0
SPB_XTD9_SHUT/TSENS/T4 0.0 0x1020 0x0
FXE_XTD9_COLB/TSENS/T1 0.0 0x20 0x0
FXE_XTD9_COLB/TSENS/T2 0.0 0x20 0x0
FXE_XTD9_PBLM/TSENS/BLADE_BOTTOM 22.780000686645508 0x20 0x0
FXE_XTD9_PBLM/TSENS/BLADE_LEFT 22.8700008392334 0x20 0x0
FXE_XTD9_PBLM/TSENS/BLADE_RIGHT 22.850000381469727 0x20 0x0
FXE_XTD9_PBLM/TSENS/BLADE_TOP 22.93000030517578 0x20 0x0
|
Now the loop is accessible to Karabo as well with the project SA1_EPS |
95
|
04 Apr 2017, 12:28 |
Alessandro Silenzi | General | Information | Temperatures from EPS loop |
This is the list of data coming directly from the PLC via its TCP client connected to the EPS PLC.
Format:
deviceName temperature status errorCode
XTD2
==================================================
SA1_XS3_SHUT/TSENS/T1 0.4000000059604645 0xa020 0x0
SA1_XS3_SHUT/TSENS/T2 0.4000000059604645 0xa020 0x0
SA1_XS3_SHUT/TSENS/T3 0.4000000059604645 0xa020 0x0
SA1_XS3_SHUT/TSENS/T4 0.4000000059604645 0xa020 0x0
SA1_XTD2_ABS/TSENS/T1 0.0 0x20 0x0
SA1_XTD2_ABS/TSENS/T2 0.0 0x20 0x0
SA1_XTD2_ATT/TSENS/A1 30.739999771118164 0x20 0x0
SA1_XTD2_ATT/TSENS/A2 1372.0 0x15020 0x0
SA1_XTD2_ATT/TSENS/A3 30.380002975463867 0x20 0x0
SA1_XTD2_ATT/TSENS/A4 31.05000114440918 0x20 0x0
SA1_XTD2_ATT/TSENS/A6 31.130002975463867 0x20 0x0
SA1_XTD2_ATT/TSENS/A7 30.78000259399414 0x20 0x0
SA1_XTD2_ATT/TSENS/A8 30.98000144958496 0x20 0x0
SA1_XTD2_ATT/TSENS/A9 33.5 0x20 0x0
SA1_XTD2_COLA/TSENS/T1 0.0 0x1020 0x0
SA1_XTD2_COLA/TSENS/T2 0.0 0x1020 0x0
SA1_XTD2_COLB/TSENS/T1 0.0 0x20 0x0
SA1_XTD2_COLB/TSENS/T2 0.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_10_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_10_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_1_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_1_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_2_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_2_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_3_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_3_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_4_T1 33.60000228881836 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_4_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_5_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_5_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_6_T1 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_6_T2 85.0 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_7_T1 33.60000228881836 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_7_T2 33.5 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_8_T1 33.60000228881836 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_8_T2 33.5 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_9_T1 33.60000228881836 0x1020 0x0
SA1_XTD2_CRL/TSENS/LENS_9_T2 33.5 0x1020 0x0
SA1_XTD2_DPS1/TSENS/FLOW 2.0300002098083496 0x20 0x0
SA1_XTD2_DPS1/TSENS/RETURN1 33.5 0x20 0x0
SA1_XTD2_DPS1/TSENS/RETURN2 2.0200002193450928 0x20 0x0
SA1_XTD2_DPS3/TSENS/FLOW 33.5 0x20 0x0
SA1_XTD2_DPS3/TSENS/RETURN1 4.160000324249268 0x20 0x0
SA1_XTD2_DPS3/TSENS/RETURN2 4.420000076293945 0x20 0x0
SA1_XTD2_PBLM/TSENS/BLADE_LEFT 32.900001525878906 0x20 0x0
SA1_XTD2_PBLM/TSENS/BLADE_RIGHT 33.5 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_BOTTOM_B4C 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_BOTTOM_W 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_LEFT_B4C 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_LEFT_W 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_RIGHT_B4C 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_RIGHT_W 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_TOP_B4C 0.0 0x20 0x0
SA1_XTD2_PSLIT/TSENS/BLADE_TOP_W 0.0 0x20 0x0
XTD9
============================================================
SA1_XTD9_PBLM/TSENS/BLADE_LEFT 24.31999969482422 0x20 0x0
SA1_XTD9_PBLM/TSENS/BLADE_RIGHT 24.810001373291016 0x20 0x0
SPB_XTD9_COLB/TSENS/T1 0.0 0x20 0x0
SPB_XTD9_COLB/TSENS/T2 0.0 0x1020 0x0
SPB_XTD9_DPS1/TSENS/FLOW 33.5 0x1020 0x0
SPB_XTD9_DPS1/TSENS/RETURN1 85.0 0x1020 0x0
SPB_XTD9_DPS1/TSENS/RETURN2 85.0 0x1020 0x0
SPB_XTD9_DPS2/TSENS/FLOW 85.0 0x1020 0x0
SPB_XTD9_DPS2/TSENS/RETURN1 85.0 0x1020 0x0
SPB_XTD9_DPS2/TSENS/RETURN2 85.0 0x1020 0x0
SPB_XTD9_PBLM/TSENS/BLADE_BOTTOM 23.05000114440918 0x20 0x0
SPB_XTD9_PBLM/TSENS/BLADE_LEFT 22.860000610351562 0x20 0x0
SPB_XTD9_PBLM/TSENS/BLADE_RIGHT 23.05000114440918 0x20 0x0
SPB_XTD9_PBLM/TSENS/BLADE_TOP 23.05000114440918 0x20 0x0
SPB_XTD9_SHUT/TSENS/T1 0.0 0x1020 0x0
SPB_XTD9_SHUT/TSENS/T2 0.0 0x1020 0x0
SPB_XTD9_SHUT/TSENS/T3 0.0 0x1020 0x0
SPB_XTD9_SHUT/TSENS/T4 0.0 0x1020 0x0
FXE_XTD9_COLB/TSENS/T1 0.0 0x20 0x0
FXE_XTD9_COLB/TSENS/T2 0.0 0x20 0x0
FXE_XTD9_PBLM/TSENS/BLADE_BOTTOM 22.780000686645508 0x20 0x0
FXE_XTD9_PBLM/TSENS/BLADE_LEFT 22.8700008392334 0x20 0x0
FXE_XTD9_PBLM/TSENS/BLADE_RIGHT 22.850000381469727 0x20 0x0
FXE_XTD9_PBLM/TSENS/BLADE_TOP 22.93000030517578 0x20 0x0
|
94
|
04 Apr 2017, 11:21 |
Tobias Haas | General | Information | Schedule after 09:30 Meeting |
Tunnel closed today. Might re-open around 14:00
Note that that we re-convene briefly at 17:00 today in MCR (Mock-up Control Room)
Vacuum Loop:
Status:
- Large number of ion pumps not responding properly (2 in XTD2, 63 in XTD9). There is the suspicion that the parameters on some ion pump controllers might be set incorrectly, such as baud rate or the bus address. The generated error code indicates a bad address.
- Test in the lab requires Ion pump controller and PCL. No setup currently readily available. Check in the tunnel required. Could take place between 1200 and 1300 in XTD2 with a ZZ. (Update: B. Racky thinks she will be done around 1400 and would prefer access after this time)
- Preparations needed to include XGM
EPS Loop:
Status:
- Temperature sensors return null value. Suspected firmware bug has been fixed and EPS loop updated by TF
- EPS to MPS interface requires testing. Should be done tomorrow
Motion Loop:
Status:
- Fixes have been applied to the MC2 lib. Tested for TECHNOSOFT driver. Should now work also for PBLMs . Tests do be done starting Wednesday
Imagers
Status:
- Camera driver for SR imager not working
- Camera driver for FEL driver working for imager in XTD2 but not for XTD9
Tasks for today:
- E. Eidam, V. Bondor, , J. Tolkiehn H. Sinn go through all ion pumps in the Silenzi list
- E. Eidam, T. Freyermuth check pump controller settings in the tunnel
- A. Koch and W. Ehsan work on Photonics Camera driver for FEL imager
Tasks for tomorrow:
- M. Planas, T. Maltezopoulos, N. Jardon, J. Eidam test XGM vacuum integration in XTD2 (not XTD9)
- N. Gerasimova, N. Gerasimova and 1 firmware expert test PBLMs in the tunnel
- T. Freyermuth tests EPS -> MPS interface
Other topics
- The two signals from MCP to EPS shall be called MCP-upstream and MCP-downstream
|
93
|
03 Apr 2017, 10:03 |
Tobias Haas | General | Information | Schedule for PLC and Karabo 3 April after 09:30 Meeting |
Tunnels closed today and tomorrow
- AE updates Vacuum and motion loop in the morning
- V. Bondar, J. Eidam and H. Sinn test vacuum in the afternoon (emphasis on understanding interlock conditions)
- A. Koch tests XTD2 imagers in the afternoon
See also https://in.xfel.eu/redmine/projects/sase1/agile_board
Problems solved on Friday last week:
- Arms 2 & 4 of SRA are now moving. Apparently spindles had mechanical resistance that resulted in error condition. After moving a few times, this appears to be gone
- One of the problematic ion pumps had the serial line disabled. However, other lines
|
92
|
31 Mar 2017, 16:02 |
NEREA JARDON | General | Information | SASE1 EPS |
Dear all,
EPS loop is running with the latest hardware updates. Today, when I was trying to update the loop, I have found that someone has powered off the EPS crate in XTD2 Rack 1.5. Please, if you have to do some work in any part of SASE 1, let us know about it.
Thank you! |
91
|
31 Mar 2017, 15:03 |
Frederike Wittmaack | General | Information | Meeting Minutes 31 March 2017 |
http://tinyurl.com/lttzrtm |
90
|
31 Mar 2017, 15:00 |
Tobias Haas | General | Information | Update of component list after weekly meeting |
|
Attachment 1: 170331-Tunnel-Components-Priority-list.xlsx
|
89
|
31 Mar 2017, 07:24 |
Liubov Samoylova | General | Information | Web cameras in SASE1 tunnels |
|
Attachment 1: TmpPhCom_CR_2017-03-31-1.pptx
|
88
|
24 Mar 2017, 15:24 |
Tobias Haas | General | Information | Update of component priority list after weekly meeting |
|
Attachment 1: 170324-Tunnel-Components-Priority-list.xlsx
|
87
|
24 Mar 2017, 13:21 |
Tobias Haas | General | Information | Schedule for PLC and Karabo Week 13 |
Day |
Motion Loop |
Vacuum Loop |
EPS Loop |
SPB Tunnel Loop |
Karabo |
Monday |
Loop up. |
Loop up. |
Loop up |
Loop inactive |
Version update by CAS 12:00 - 18:00 |
Tuesday |
Loop up. |
Loop up. |
Loop up |
Loop inactive |
Running and no change |
Wednesday |
Loop up. |
Loop up |
Loop up |
AE brings up loop |
Running and no change |
Thursday |
Loop up |
Loop up |
Loop up |
AE brings up loop |
Running and no change |
Friday |
Loop up |
Loop up |
Loop up |
Loop up |
Running and no change |
|
86
|
23 Mar 2017, 10:06 |
NEREA JARDON | General | Information | Motion up |
Dear all,
The Motion loop is up and running again.
Thank you! |
85
|
22 Mar 2017, 16:39 |
Andreas Koch | XTD2 | Information | Pop-In II-45 Karabo test |
Trigger signal now available at imager. First Karabo tests of camera device with trigger successful. Detailed
tests continue. |
84
|
22 Mar 2017, 16:28 |
NEREA JARDON | General | Information | Motion loop |
Dear all,
tomorrow morning at 10h am, we will need the Motion PLC for roughly half hour to do some tests. During this time the PLC will be stop.
|
83
|
22 Mar 2017, 15:05 |
NEREA JARDON | General | Information | Motion Loop |
FYI. The Motion loop is again up and running. |
82
|
17 Mar 2017, 15:21 |
Adriano Violante | General | Information | Loop status schedule for KW12 |
Dear all,
find here the foreseen loop status for KW12. The schedule could change. All changes will be notified by entries in the logbook.
Day |
Motion |
Vacuum |
EPS |
Other |
Monday |
Loop is up. |
Loop up. |
Loop up |
|
Tuesday |
Loop is up. |
Loop down. AE updates loop (maybe short ) |
Loop up |
|
Wednesday |
Loop down. AE updates loop |
Loop up |
Loop up |
|
Thursday |
Loop up |
Loop up |
Loop up |
|
Friday |
Loop up |
Loop up |
Loop up |
|
|
81
|
17 Mar 2017, 12:11 |
Thomas Tschentscher | General | Information | Updated Tunnel component status list |
Updated list of tunnel high priority components after SASE1 Readiness mtg this morning. The list has also been sent for comments/clarifications to the involved Groups/People. |
Attachment 1: 170317-Tunnel-Components-Priority-list.xlsx
|
80
|
17 Mar 2017, 10:49 |
NEREA JARDON | General | Information | Loops up |
Dear all, Vacuum and Motion loops are running again.
Thank you, |
79
|
16 Mar 2017, 16:54 |
NEREA JARDON | General | Information | Fuses replacement |
Dear all,
Tomorrow in the morning is needed to add some fuses in the PLCs crate, therefore Vacuum and Motion would be down for more or less one hour from 9am. I will notify you when the PLCs are available to work again.
Thank you, |
78
|
16 Mar 2017, 13:34 |
Torben Falk | General | Feedback | Wiring status |
Wiring status SASE 1:
Wiring progress:
- Internal wiring of the XGM in XTD 9 is done.
- Vacuum part wiring of the XGM in XTD 9 is done (ready for local Beckhoff test).
- Gas Panel wiring of the XGM in XTD 9 is done.
- Crate wiring (ADAM & Femto crate) of the XGM in XTD 9 is done.
Upcoming work XTD 2:
- Serial connection from Beckhoff to TCP 350.
- Change cold plug cables into halogenfree cables.
Upcoming work XTD 9:
- INHIBIT connection Iseg HV crate.
- Serial connection from MTCA to RVC 300.
Upcoming work XTD 10:
- Vacuum part wiring of XGM.
- Gas Panel wiring of XGM.
- Internal wiring of XGM.
- Installing ADAM & Femto crate.
- Measure cable lengths for Imager and prepare cables.
|