  OPERATION-2024 logbook, Contact: F.Wolff-Fabris, A.Galler, H.Sinn, Page 6 of 11  Not logged in ELOG logo
ID Date Author Group Subject Text Attachments
  113   26 May 2024, 23:23 Romain LetrunSPBShift summaryX-ray delivery


6.0 keV, up to 202 pulses
at 564 kHz, 1.8-1.9 mJ.
Stable
  
  112   26 May 2024, 21:56 Thomas BaumannSQSStability IssueWe asked the machine for two color mode
in the morning. Tuning gave good results
at first (1.6mJ second color, 100uJ first
  
  111   26 May 2024, 00:23 Romain LetrunSPBShift summaryX-ray delivery


6.0 keV, up to 202 pulses
at 564 kHz and 101 at 282 kHz, 0.8-1.6 mJ
Low
  
  110   25 May 2024, 02:38 Rebecca BollSQSIssueToday in the afternoon, SASE1 was tuned
(a description of the activities in att 4).
We now realize that this has in some form
 Run_177_vs_247.pngScreenshot_from_2024-05-25_00-44-46.pngScreenshot_from_2024-05-25_01-03-29.pngScreenshot_from_2024-05-25_01-36-54.png 
  109   19 May 2024, 15:20 Antje TrappXROHED 6keV after Euler MDL   Screenshot_from_2024-05-19_15-18-51.png 
  108   19 May 2024, 14:49 Antje TrappXROM1 - M2 - M3 euler fine tuning geometriy parametersWe fine tuned geometry parameters for linear
effects on X motion (parallel offset) for
all three mirrors.
 Screenshot_from_2024-05-19_15-18-51.png 
  107   17 May 2024, 10:42 Dirk RaiserSQSStatusLaser status:

After the laser issues listed in https://in.xfel.eu/elog/OPERATION-2024/99 the
  
  106   14 May 2024, 11:49 Romain LetrunSPBShift summaryX-ray delivery


11.56 keV, 1-197 pulses
@ 564 kHz, 2.6 mJ.


Optical
  
  105   14 May 2024, 09:56 Andreas KochXPDIssueEPS issue for Transmissive imager
SA1 (OTRC.2615.T9) w.r.t Operation eLog #96

The motor screen positions w.r.t.
  
  104   13 May 2024, 10:36 Romain LetrunSPBShift summaryX-ray
delivery


11.56
  
  103   13 May 2024, 08:48 Ulrike BoesenbergMIDShift summaryWeekend summary:

Overall stable beam delivery with
300bunches @18keV and 750uJ
  
  102   12 May 2024, 07:35 Romain LetrunSPBShift summaryX-ray
delivery


11.56 keV, 1-352 pulses
  
  101   11 May 2024, 07:20 Romain LetrunSPBShift summaryX-ray
delivery


11.56 keV, 1-352 pulses
  
  100   10 May 2024, 07:06 Romain LetrunSPBShift summaryX-ray
delivery


11.56 keV, 1-352 pulses
  
  99   10 May 2024, 00:04 Rebecca BollSQSIssueour pp laser experienced timing jumps by
18 ns today. this happened for the first
time at ~7:30 in the morning without us noticing
  
  98   09 May 2024, 10:45 Tommaso MazzaSQSotherwe needed SASE1 to be set to 0 pulses briefly
to check alignment in our experiment.

The FXE control hutch was empty.
  
  97   09 May 2024, 07:14 Romain LetrunSPBShift summaryX-ray
delivery


11.56 keV, 1-352 pulses
  
  96   08 May 2024, 13:51 Raśl Villanueva-GuerreroPRCIssueDear all,

Due to a probable issue at the
SA1 Transmissive imager, the "OUT"
 image_2024-05-08_135756593.pngimage_2024-05-08_140027070.pngimage_2024-05-08_140101131.pngimage_2024-05-08_140228955.png 
  95   05 May 2024, 00:25 Konopkova ZuzanaHEDExperiment summary
proposal 5700 finished on 04.05.
The experiment used 352 pulses at
4.5 MHz and 18 keV to X-ray heat
  
  94   03 May 2024, 23:31 Juncheng ESPBShift summaryX-ray delivery

- 9.3 keV, 3.1 mJ, 214 pulses/train
at 1.1 MHz and 132 at 0.5 MHz
  