Status, posted by Frederik Wolff-Fabris on 14 Oct 2023, 09:48
|
Machine went down overnight (4AM and 6AM) and could not be properly restarted by BKR.
Ongoing tuning is proceeding with RC onsite since 6AM; Instruments are informed and in direct contact to BKR.
Status 09:45AM: SA1 ~3mJ; SA2: ~500uJ; SA3 being restarted |
Shift summary, posted by Chan Kim on 14 Oct 2023, 04:04
|
X-ray delivery
7.8 keV, up to 260 pulses at 1.1MHz, ~3 mJ
Optical laser delivery
PP laser, stable delivery
Achievements/Observations |
Issue, posted by Theophilos Maltezopoulos on 13 Oct 2023, 10:19
|
An XGM has two single-shot detectors, XGMD and HAMP.
The XTD2 XGMD amplifiers are damaged, thus I operate the XTD2 XGM with HAMP, which I usually use at > 18 keV.
In summary, the XTD2 XGM is fully operational, but I do not have a spare detector any more! Thus, a ZZ is organized for Monday 16.10. around |
Shift summary, posted by Chan Kim on 13 Oct 2023, 07:06
|
X-ray delivery
7.8 keV, up to 260 pulses at 1.1MHz, >4 mJ
Optical laser delivery
PP laser was down since 00:48.
Achievements/Observations |
Shift summary 11.10.2023, posted by Tokushi Sato on 12 Oct 2023, 02:00
|
Staff: JK, CK, KL, AS
X-ray delivery
8.4 keV, up to 260 pulses at 1.1MHz, 3.5 mJ
Optical laser delivery |
Shift summary, posted by Abhisakh Sarma on 11 Oct 2023, 06:22
|
X-ray delivery
7.8 keV, up to 30 pulses at 94 kHz, 3 mJ
Optical laser delivery
No laser
Achievements/Observations |
Shift end, posted by Harald Sinn on 03 Oct 2023, 22:58
|
End of Euler shift: all 3 SASE2 mirrors are now working with the Euler MDL.
We left the beamline aligned to HED, with M1,M2 on Pt for upcoming HED experiment at 18 keV.
Pre-absorber closed, CRL1 out, Solid attenuater with some diamonds. |
Euler calibration and Mirror setpoints, posted by Antje Trapp on 03 Oct 2023, 22:51
|
euler MDL was calibrated for all three mirrors.
Optics setpoints saved in XRO setpoints for MID and HED
|
M3 vertical motors calibration - EulerMDL, posted by Antje Trapp on 02 Oct 2023, 21:48
|
Second iteration and sanitty test for vertical mirror motion (Y) and vertical beam alignment (ROLL)
Vertical motors were calibrated and offsets saved in Euler MDL (no calibration of motors done so far - this should be performed during ramp up
after WMP) |
Shift summary, posted by Tokushi Sato on 01 Oct 2023, 23:06
|
X-ray delivery
6.3 keV, 3-4 mJ/pulse, 1-352 pulses at 1.13 MHz
Optical laser delivery
PP laser, 1030 nm, 352 pulses at 1.1 MHz, stable delivery
ns laser for rayleigh scattering, stabe delivery
Achievements/Observations |
Morning shift summary, posted by Giuseppe Mercurio on 01 Oct 2023, 14:48
|
# Morning shift summary
Giuseppe, Martin
* achievements |
Shift summary, posted by Johannes Moeller on 01 Oct 2023, 02:00
|
HXRSS at 8.8 keV, 1, 60 or 350 pulses. Quite stable seeding performance
loaded new sample (HGW) in the morning
measured full temperature series on HGW during the day
problem with vacuum
in the cryostat-chamber, which triggered the interlocked during the data taking and blocked AGIPD for some temperatures
focussing optimized |
Shift summary, posted by Tokushi Sato on 30 Sep 2023, 23:08
|
X-ray delivery
6.3 keV, 3-4 mJ/pulse, 1-352 pulses at 1.13 MHz
Optical laser delivery
PP laser, 1030 nm, 352 pulses at 1.1 MHz, stable delivery
ns laser for rayleigh scattering, stabe delivery
Achievements/Observations |
Issue, posted by Romain Letrun on 30 Sep 2023, 10:11
|
On multiple occasions this morning, the number of bunches was reduced to 1 without actions from our side.
Looking at the history of SA1_XTD2_BUNCHPATTERN/MDL/CONFIGURATOR, we noticed changes were applied by this device, presumably originating from
one of the watchdogs in SA1. This kind of silent changes is particularly inconvenient and could be easy to miss if one is not constantly monitoring that |
Shift summary, posted by Tokushi Sato on 29 Sep 2023, 23:13
|
X-ray delivery
6.3 keV, 3-4 mJ/pulse, 1-352 pulses at 1.13 MHz
Optical laser delivery
PP laser, 1030 nm, 226 pulses at 1.1 MHz, stable delivery
ns laser for rayleigh scattering, stabe delivery
Achievements/Observations |
Shift summary, posted by Laurent Mercadier on 29 Sep 2023, 22:59
|
# Late shift summary 29.09.2023
Laurent, Phuong
## Achievements |
Shift summary, posted by Romain Letrun on 29 Sep 2023, 08:30
|
Shift sumary for 29.9.2023
X-ray delivery |
Shift summary, posted by Johannes Moeller on 29 Sep 2023, 00:35
|
1, 60 and 350 pulses at 8.7keV, HXRSS
*focus characterization CRL2 lens 3,5,6
*Si 20nm XPCS with 20 and 50 pulses to evaluate the contrast |
Shift summary, posted by Romain Letrun on 28 Sep 2023, 07:20
|
Shift summary for 27.9.2023
X-ray delivery
6.3 keV, 3-4 mJ/pulse, 1-352 pulses at 1.13 MHz
Optical laser delivery |
SCS Night Shift Summary, posted by Benjamin van Kuiken on 27 Sep 2023, 07:51
|
Achievements
Characterized optical laser spot at sample
Problems
FEL beam had very unstable intensity and spectrum. As a result no useful data could be collected during the night
FEL pointing |