Shift summary, posted by Tokushi Sato on 03 Mar 2023, 23:27
|
X-ray delivery
- 9.3 keV, 202 pulses, 564 kHz, intensity slope was flat
Optical laser delivery
- 800 nm, 68 pulses, 188 kHz. stable delivery
- ns laser for illumination
Achievements/Observations
- Continue nanofocusing setup with pump-probe experiment
- Continue Collecting TR-SFX data
Issues
- Run_Controller problem still persists, it stopped without any action from us
|
Shift summary, posted by Tokushi Sato on 04 Mar 2023, 22:55
|
X-ray delivery
- 9.3 keV, 202 pulses, 564 kHz, intensity slope was fine
Optical laser delivery
- 800 nm, 68 pulses, 188 kHz. stable delivery
- ns laser for illumination
Achievements/Observations
- Continue nanofocusing setup with pump-probe experiment
- Continue Collecting TR-SFX data
Issues
- uTCA timing was shifted about 3 ns against X-ray and PP-laser
|
Shift summary, posted by Juncheng E on 05 Mar 2023, 23:13
|
X-ray delivery
- 9.3 keV, 202 pulses, 564 kHz, intensity slope was fine
Optical laser delivery
- 800 nm, 68 pulses, 188 kHz. stable delivery
- ns laser for illumination
Achievements/Observations
- Continue nanofocusing setup with pump-probe experiment
- Continue Collecting TR-SFX data
|
Shift end, posted by Jayanath Koliyadu on 21 Mar 2023, 23:36
|
Staff: JB, PV, TS, RL, RdW, JK, AR
X-ray delivery
- 1-165 pulses, 1.1 MHz, upto 400 uJ @ 50 pC
Optical laser delivery
Achievements/Observations
- NKB focus optimization
- Beam alignment until IBS
- Photodiode alignment
- Alignment of fixed target in the beam
- Tests with fixed target motion in vacuum
- Collected few runs with low transmission at 8 keV and 9 keV
|
Shift end, posted by Adam Round on 22 Mar 2023, 21:49
|
X-ray delivery
- 9 keV 1 to 165 pulses ~ 300 mj per pulse - stable delivery during the day
Optical laser delivery
- ns lasers for illumination only
Achievements/Observations
- Focus alignment
- found illumination / shield (100 micron) conditions to optimise background on detector
- observed that the flourecence signal on the diode was very low and this appears corelated with drift in the focus - after focus optimisation signal was again visible
- several runs collected with varying attenuation with the aim to try to corelate flourecence signal on diode with beam intensity
Issues
- Too high background from sample at full transmission required exchange of copper shield form 50 to 100 microns
- disc detaching from motor spindle (twice) - first time disc blocked gate valve, second bolt and washer are in the gate valve mechanisme space
- in both cases detector had to be warmed to allow venting.
|
Issue, posted by Romain Letrun on 23 Mar 2023, 11:38  
|
When using 1.13 MHz X-ray repetition rate, SASE1 HIREX is capturing two pulses in a single frame giving the impression that there are more peaks within the spectrum than there are in reality.
This was verified by recording data with one and two pulses per train, which are shown in attachment.
The spectral integral/intensity in GOTTHARD frame 6, the first with data, is twice larger with two pulses compared to one pulse per train (attachments 1 and 2).
The number of peaks is consistently higher with two pulses compared to one pulse (attachment 3). |
Status, posted by Romain Letrun on 23 Mar 2023, 14:31  
|
After SASE1 HIREX GOTTHARD reconfiguration, we now get a single pulse per frame. This was verified by comparing data from HIREX recorded with 564 kHz and 1.13 MHz X-ray repetition rates. Both intensity and number of peaks is comparable for the two repetition rates. |
Shift end, posted by Jayanath Koliyadu on 23 Mar 2023, 23:24
|
X-ray delivery
- 1-165 pulses, 1.1 MHz - 28.2 kHz, upto 400 uJ @ 50 pC
Optical laser delivery
Achievements/Observations
- Optimized sample setup for data collection
- Calibrated photodiode @ 8keV.
- ADC signal was saturated with amplified photodiode signal.
- Removed the amplifier and calibrated photodiode again.
- ASE signal is visible without the amplifier
- Optimized ASE signal by optimizing the focus and target position in focus
- Checking and optiming the focus everytime chaning the sample disk seems to improve the signal
- Collected data at 8 keV and 9 keV for about 1-2 hours
|
Shift end, posted by Jayanath Koliyadu on 24 Mar 2023, 23:14
|
X-ray delivery
- 1-165 pulses, 1.1 MHz - 28.2 kHz, upto 350 uJ @ 50 pC
Optical laser delivery
Achievements/Observations
- Collected data for 3 to 4 hours with different samples
- Data collection at lower repetiton rate (113 kHz) with less number of pulses
|
Shift end, posted by Jayanath Koliyadu on 25 Mar 2023, 23:18
|
X-ray delivery
- 1-165 pulses, 1.1 MHz - 56.4 kHz, upto 350 uJ @ 50 pC
Optical laser delivery
Achievements/Observations
- Collected data for 3 to 4 hours with different samples
- Data collection at lower repetiton rate (113 kHz) with less number of pulses
- Data to characterize the divergence of ASE collected
|
Shift end, posted by Jayanath Koliyadu on 26 Mar 2023, 23:27
|
X-ray delivery
- 1-165 pulses, 1.1 MHz - 56.4 kHz, upto 350 uJ @ 50 pC
Optical laser delivery
Achievements/Observations
- Collected data for about 6 hours with different samples
- Data collection at lower repetiton rates with less number of pulses
- Data to characterize the divergence of ASE collected
- Photodiode calibrated at 8 keV again
|
Shift summary, posted by Tokushi Sato on 30 Mar 2023, 06:53
|
X-ray delivery
- 1-202 pulses, 564, 282, 141 kHz, stable delivery
Optical laser delivery
- 800nm, 50 fs, 282 kHz, stable delivery
Achievements/Observations
- Alignment for Pump-probe experiment was finished
- Sample was tested
Issues
|
Shift summary, posted by Tokushi Sato on 31 Mar 2023, 06:59
|
X-ray delivery
- 1-202 pulses, 564, 282, 141 , 70.5 kHz, stable delivery
Optical laser delivery
- 800nm, 50 fs, 282 kHz, stable delivery
Achievements/Observations
- Resasnable amout of data was collected
- Sample was tested
Issues
|
Shift summary, posted by Tokushi Sato on 01 Apr 2023, 06:51
|
X-ray delivery
- 1-202 pulses, 564 kHz, stable delivery
- Beam was down from 06:08
Optical laser delivery
- 800nm, 50 fs, 282 kHz, stable delivery
Achievements/Observations
- Resasnable amout of data was collected
Issues
|
Shift summary, posted by Johan Bielecki on 07 Apr 2023, 23:03
|
Beam delivery for proposal 3378
Achievements/Observations
- Collected data on liquid H20 and D20
- Found conditions where only ice were seen. approx. 4h of ice data taken. Starting to look at correlation maps
- Background at 0.88mm nozzle distance measured
To do for next shift:
Continue taking data
|
Shift summary, posted by Johan Bielecki on 08 Apr 2023, 22:52
|
Beam delivery for proposal 3378
Achievements/Observations
- Collected large amounts of data for the user program on water crystallisation and angular correlations
To do for next shift:
Continue taking data |
Shift summary, posted by Romain Letrun on 19 Apr 2023, 07:04
|
X-ray delivery
- 12.0 keV, 1.3 mJ, 1-168 pulses @ 564 kHz
- Decaying intensity between 1:20 and 2:40, otherwise stable delivery.
Optical laser delivery
- 1030 nm compressed, THG
- Stable delivery
Achievements/Observations
- Optimised PP laser THG conversion efficiency.
- PP laser spatial and temporal overlap with water jet.
- Collected lysozyme diffraction for detector geometry.
|
Shift summary, posted by Romain Letrun on 20 Apr 2023, 06:58
|
X-ray delivery
- 12.0 keV, 1.3 mJ, 1-168 pulses @ 564 kHz.
- Stable delivery.
Optical laser delivery
- 1030 nm compressed, THG.
- Stable delivery.
Achievements/Observations
- Collected static and TR-SFX data.
|
Shift summary, posted by Romain Letrun on 21 Apr 2023, 04:33
|
X-ray delivery
- 12.0 keV, 1.3 mJ, 1-168 pulses @ 564 kHz
- Cryo issue at 3:33
Optical laser delivery
- 1030 nm compressed, THG.
- Stable delivery.
Achievements/Observations
- Collected TR-SFX data. Smooth sample jetting.
Issues
- Beam down, shift ended earlier.
|
Shift summary, posted by Richard Bean on 26 Apr 2023, 01:03
|
SPB/SFX User shift 1 3333
X-ray delivery
Achievements/Observations
-
Silicon wafer post sample attenuator (240um, ~10% transmssion @ 9.3 keV) was mounted in-front of the AGIPD detector. elog: 3
-
Beamline is aligned for the NKB trajectory and the x-ray focus size of 300 nm being achieved. elog: 4
-
Copper flat field including 240 um silicon wafer attenuator. elog : 7
-
Lysozyme and Photosystem-II data (@ 41 mm AGIPD Z motor value) elog: 5
-
Fixed medium gain used initially, later switched to adaptive gain to allow high gain for peaks behind Si attenuator mask. Switch of both calibration pipelines..
-
data at full transmission. Move to medium gain for water ring outside Si attenuator
-
Several blocked nozzles, at least potentially caused by never filtered sample.
Issues
-
Problems with post calibration analysis, observing 'disk quota error' - SPB/SFX RC to investigate with instrument data team and DRC
-
problems with data calibration - SPB/SFX RC to investigate with instrument data team and DRC
Instrument status
-
AGIPD off and warm
-
AGIPD gate valve OPEN and pinned.
-
Attenuators set to thickest diamond.
-
Vacuum valves closed.
-
He valve closed.
-
Sample valves cleaned.
-
ns laser off.
-
Sample chamber and AGIPD turbos OFF, rough pumping ON
To do for next shift
|