other, posted by Chan Kim on 25 Nov 2023, 19:56
|
Beam drift in the horizontal direction (XTD9_XGM).
From ~16:00, X-ray beam started to drift in the horizontal direction. In total, ~0.3 mm drift observed within 2-3 hours.
|
night shift summary, 22.10.2023, posted by Laurent, Phuong on 22 Oct 2023, 07:34
|
Night shift summary 22.10.2023
Laurent, Phuong
Achievement:
-Collecting static RIXS data at different FEL repitition rates |
night shift summary and end of beamtime, posted by Andreas, Martin on 24 Apr 2023, 15:16
|
achievements:
- finished SAXS data recording till 8am on time-resolved skyrmion nucleation and field dependence
- the setup is sensitive to beam transport drifts due to the closed hor-SLIT and the pinhole in FFT. were able to recover beam intensity by simple |
night shift summary and end of beamtime, posted by Andreas, Martin on 24 Apr 2023, 15:16
|
achievements:
- finished SAXS data recording till 8am on time-resolved skyrmion nucleation and field dependence
- the setup is sensitive to beam transport drifts due to the closed hor-SLIT and the pinhole in FFT. were able to recover beam intensity by simple |
night shift summary, posted by Giuseppe Mercurio on 06 May 2023, 06:53
|
achievements:
- measured delay scans at sample tilted by 20 degree
problems: |
night shift summary, posted by Giuseppe Mercurio on 06 May 2023, 06:53
|
achievements:
- measured delay scans at sample tilted by 20 degree
problems: |
night shift summary, posted by Giuseppe Mercurio, Teguh Asmara on 04 Aug 2023, 07:10
|
achievements:
changed the LEPM to optimize resolution
found 140 meV
problems:
were not able to recover settings found because it is difficult to reproduce LEPM positions
plan: |
night shift summary, posted by Andreas Scherz / Eugenio Paris on 26 Oct 2023, 07:13
|
Night shift summary
Achievements:
- Recovered time0 on SiN (time0 moved >20ps after FEL beam loss in the evening) |
morning shift summary, posted by Natalia, Zhong on 05 Feb 2023, 12:32
|
achievements:
- Viking spectrometer set up in 8th order around 1280eV and calibrated
problems: |
morning shift summary, posted by Benjamin, Nahid, Raphael, Philippe, Victoria, Timo on 15 Mar 2023, 17:01
|
Achievements
Found RIXS signal from liquid jet
Measured static RIXS and PFY-XAS spectrum of Co(cp)(CO)2
Problems
hRIXS detector has a data latency issue and images were not being recorded in the DAQ. This required ~2-3 hours to solve plus time lost |
morning shift summary, posted by Loic Le Guyader on 04 May 2023, 14:34
|
achievements
we change the DSSC timing to record the first pulse
sample was getting damaged with 26mJ/cm2 and scattering of the sample
was changed so we used lower fluence to observe t0 on the sample
changed to 2nd mono order, 20% GATT transmission and exit slit to 0.3 mm. The |
morning shift summary, posted by Giuseppe Mercurio on 05 May 2023, 14:56
|
achievements
with help from LAS OCD, we got the PPL synchronized again with optical lock and close to the initial t0 on the sample
we found
t0 on the sample again
collected data with magnetic field
initial setup of damnit/amore for semi-automatized data processing
problems |
morning shift summary, posted by Giuseppe Mercurio on 06 May 2023, 14:42
|
achievements
finished recording dataset at 20degree
changed for sample with smaller grains at normal incidence and moved DSSC to 1.2m
OL
induced some change of the sample but the scattering ring remains and then stabilize
started collecting data
problems |
morning shift summary, posted by Giuseppe Mercurio on 07 May 2023, 14:47
|
achievements
exchanged He dewar and managed to cool down the sample again after vacuum issue last night
started collecting additional scattering
data with alternating magnetic field on large nanoparticles sample
problems |
moning shift summary, posted by Nahid, Ben on 19 Mar 2023, 15:03
|
Achievements:
measured the new sample, Silane, with different time delays
Problems
Tuning of SASE2 led to a 50% decrease in the SCS XGM intensity without affecting the SASE3 intensity. It also caused a jump in the BAM |
late shift summary 2nd day, posted by Luigi, Laurent on 15 Feb 2023, 23:05
|
Achievememts:
optimised the beam rep rate to value of 140KHz for a better signal
changed nozzles and refilled the reservoir
Improved
notebook for data analysis
Cammille made an online tool to see correlations between Viking and XGM --> very useful!
Night |
late shift summary, posted by Laurent Mercadier, Luigi Adriano on 17 Feb 2023, 02:24
|
2 color mode
Achievements
Fluence scan
delay scan to identify cross talk of two colors
Optimized beam size
|
late shift summary, posted by bouffetier on 19 Feb 2023, 19:51
|
19 Feb 2023,15:30 Shift handover
Runs will be added in the general Elog for data runs and acqusitions (Elog-4)
|
late shift summary, posted by Giuseppe Mercurio and Sergii on 02 Mar 2023, 22:58
|
achievements:
knife edge scans of OL to find lens position corresponding to the smallest beam size
knife edge scans of FEL to determine
the position to proceed for spatial overlap
liquid jet was set up and it's running since afternoon
measured x-ray absortion via |
late shift summary, posted by Sergii, Andreas on 04 Mar 2023, 23:04
|
Achievements:
- we replaced broken SMA cable, and added an angle-connector at sample holder to aid the sample rotation when moving diagnostics to the flat
jet |