| ID | Date | Author | Group | Subject | Text |  |  | 88 | 19 Mar 2023, 02:01 | Johannes Moeller |  | shift summary | upper and lower branch of SDL aligned
 
 beamsizes
 and angular mismatch characterized
 
 
 vacuum
 leak of flight path fixed
 side
 |   |  | 87 | 18 Mar 2023, 01:45 | Johannes Moeller |  | shift summary | stable HXRSS delivery at 8.99 keV,
 1 bunch. XGM intensity during the day decreased
 from 750 uJ to 600 uJ.
 Vacuum
 |  |  | 86 | 17 Mar 2023, 23:43 | Robert, Zhong, Manuel | SCS | Late shift summary 17.03.2023 | Activities: 
 
 continued tr-RIXS scans
 tried
 to find ways to mitigate the energy drifts
 |  |  | 85 | 17 Mar 2023, 01:48 | Johannes Moeller | MID | Shift summary | The intensity of the Seeding decreesed from 850 uJ to 550 uJ during the time between
 20:00 and 02:00.
 |   |  | 84 | 16 Mar 2023, 01:35 | Johannes Moeller |  | End of shift | Stable HXRSS delivery with >800 uJ, 1 bunch, 8.99 keV.
 
 Re- Alignment of X-ray beam performed.
 |   |  | 83 | 16 Mar 2023, 00:26 | Robert, Manuel | SCS | Shift summary, late 2023.03.15 | Activities: 
 
 Found coarse and fine timing
 between FEL and PPL at 266nm
 Set
 |  |  | 82 | 15 Mar 2023, 17:01 | Benjamin, Nahid, Raphael, Philippe, Victoria, Timo | SCS | morning shift summary | Achievements 
 
 Found RIXS signal from
 liquid jet
 Measured static RIXS
 |  |  | 81 | 15 Mar 2023, 01:50 | Johannes Moeller |  | shift summary | HXRSS delivery, 600 - 700 uJ, 1
 bunch, 8.991 keV. Pedestal visibly in HIREX,
 not checked with MID spectrometer yet.
 beamline
 |  |  | 80 | 14 Mar 2023, 20:26 | Harald Sinn | PRC | Issue | SCS could only use two pulses, because the SXP imager was still in the beam and
 SXP shutter open.
 |  |  | 79 | 14 Mar 2023, 14:40 | Harald Sinn | PRC | Issue | In order to optimise the performance of SASE2 self seeding, a stronger compression
 setting is required.
 |  |  | 78 | 14 Mar 2023, 10:56 | Harald Sinn | PRC | Issue | The longitudinal feedback on SA1/3 was swicthed off by mistake over night. When
 it will be switched on, the beam may wiggle
 |  |  | 77 | 11 Mar 2023, 12:46 | Frederik Wolff-Fabris | PRC | SA2 status | The SA2 XTD1 XGM is current offline since Saturday morning.
 
 Yesterday, Friday, it already started
 |  |  | 75 | 06 Mar 2023, 06:48 | Ulf Zastrau | HED | Shift summary | X-ray delivery stable in intensity, 1300-1400 mJ at 8150 eV SASE.
 
 user experiment 3430 (Zastrau /
 |  |  | 76 | 06 Mar 2023, 06:20 | Teguh, Luigi | SCS | Night shift summary 05.01.2023 | Achievements: 
 1. Continued measuring time-resolved
 and static RIXS on water (run table in elog
 |  |  | 74 | 05 Mar 2023, 23:13 | Juncheng E | SPB | Shift summary | X-ray delivery 
 
 9.3 keV, 202 pulses, 564
 kHz, intensity slope was fine
 
 
 Optical
 |  |  | 73 | 05 Mar 2023, 23:04 | Sergii, Andreas | SCS | Late shift summary 05.03.2023 | Achievments 
 -RIXS scans at different delay
 times and x-ray energies
 |  |  | 72 | 04 Mar 2023, 23:04 | Sergii, Andreas | SCS | late shift summary | Achievements: 
 - we replaced broken SMA cable,
 and added an angle-connector at sample holder
 |  |  | 71 | 04 Mar 2023, 22:55 | Tokushi Sato | SPB | Shift summary | X-ray delivery 
 
 9.3 keV, 202 pulses, 564
 kHz, intensity slope was fine
 
 
 Optical
 |  |  | 70 | 04 Mar 2023, 07:00 | Teguh, Luigi | SCS | Night Shift Summary on 04.03.2023 | Achievements: 
 - Improved the vacuum of the chamber
 slightly
 |  |  | 69 | 03 Mar 2023, 23:27 | Tokushi Sato | SPB | Shift summary | X-ray delivery 
 
 9.3 keV, 202 pulses, 564
 kHz, intensity slope was flat
 
 
 Optical
 |  |  |