Group Selection Page HELP DOC Controls Group Data Analysis Group ITDM WP76 DET Vacuum XRO EEE WP78 WP74 FXE SCS SPB MID HED SQS SXP Sample Environment Photon Commissioning Team Operation PSPO XO TS
OPERATION-2024 OPERATION-2023 OPERATION-2022 OPERATION-2021 OPERATION-2020 OPERATION-2019 SASE1-2018 SASE1-2017 Experiment data
  OPERATION-2023 logbook, Contact: F.Wolff-Fabris, A.Galler, L.Samoylova, H.Sinn, Page 5 of 24  Not logged in ELOG logo
ID Date Author Group Subject Text Attachments
  389   14 Oct 2023, 09:48 Frederik Wolff-FabrisPRCStatusMachine went down overnight (4AM and 6AM)
and could not be properly restarted by BKR.

Ongoing tuning is proceeding with
  
  388   14 Oct 2023, 04:04 Chan KimSPBShift summaryX-ray delivery


7.8 keV, up to 260 pulses
at 1.1MHz, ~3 mJ


Optical
  
  387   13 Oct 2023, 10:19 Theophilos MaltezopoulosXPDIssueAn XGM has two single-shot detectors, XGMD
and HAMP.

The XTD2 XGMD amplifiers are damaged,
  
  386   13 Oct 2023, 07:06 Chan KimSPBShift summaryX-ray delivery


7.8 keV, up to 260 pulses
at 1.1MHz, >4 mJ


Optical
  
  385   12 Oct 2023, 02:00 Tokushi Sato Shift summary 11.10.2023Staff: JK, CK, KL, AS

X-ray delivery


8.4 keV, up to 260 pulses
  
  384   11 Oct 2023, 06:22 Abhisakh SarmaSPBShift summaryX-ray delivery


7.8 keV, up to 30 pulses
at 94 kHz, 3 mJ


Optical
  
  383   03 Oct 2023, 22:58 Harald SinnXROShift endEnd of Euler shift: all 3 SASE2 mirrors
are now working with the Euler MDL.

We left the beamline aligned to
  
  382   03 Oct 2023, 22:51 Antje TrappXROEuler calibration and Mirror setpointseuler MDL was calibrated for all three
mirrors.

Optics setpoints saved in XRO setpoints
 HED_Pt_M3_B4C_2023-10-03_22-53-10.pngMID_Pt_stripe_2023-10-03_22-48-46.png 
  381   02 Oct 2023, 21:48 Antje TrappXROM3 vertical motors calibration - EulerMDLSecond iteration and sanitty test for vertical
mirror motion (Y) and vertical beam alignment
(ROLL)
 HED_beam_2023-10-03_16-54-31.pngM3_setpoints_2023-10-03_16-52-53.png 
  380   01 Oct 2023, 23:06 Tokushi SatoSPBShift summaryX-ray delivery


6.3 keV, 3-4 mJ/pulse,
1-352 pulses at 1.13 MHz


Optical
  
  379   01 Oct 2023, 14:48 Giuseppe MercurioSCSMorning shift summary# Morning shift summary

Giuseppe, Martin

* achievements
  
  378   01 Oct 2023, 02:00 Johannes MoellerMIDShift summary
HXRSS
at 8.8 keV, 1, 60 or 350 pulses. Quite stable
seeding performance
  
  377   30 Sep 2023, 23:08 Tokushi SatoSPBShift summaryX-ray delivery


6.3 keV, 3-4 mJ/pulse,
1-352 pulses at 1.13 MHz


Optical
  
  376   30 Sep 2023, 10:11 Romain LetrunSPBIssueOn multiple occasions this morning, the
number of bunches was reduced to 1 without
actions from our side.
 Screenshot_from_2023-09-30_10-00-26.png 
  375   29 Sep 2023, 23:13 Tokushi SatoSPBShift summaryX-ray delivery


6.3 keV, 3-4 mJ/pulse,
1-352 pulses at 1.13 MHz


Optical
  
  374   29 Sep 2023, 22:59 Laurent MercadierSCSShift summary# Late shift summary 29.09.2023

Laurent, Phuong
## Achievements
  
  373   29 Sep 2023, 08:30 Romain LetrunSPBShift summaryShift sumary for 29.9.2023

 

X-ray delivery
  
  372   29 Sep 2023, 00:35 Johannes MoellerMIDShift summary
1,
60 and 350 pulses at 8.7keV, HXRSS

*focus characterization CRL2 lens
  
  371   28 Sep 2023, 07:20 Romain LetrunSPBShift summaryShift summary for 27.9.2023

X-ray delivery


6.3 keV, 3-4 mJ/pulse,
  
  370   27 Sep 2023, 07:51 Benjamin van KuikenSCSSCS Night Shift SummaryAchievements


Characterized optical laser
spot at sample


Problems
 SCSPopinOthOrder_270923.png 
ELOG V3.1.4-7c3fd00