| ID | Date | Author | Group | Subject | Text |  |  | 204 | 23 Nov 2024, 10:23 | Jan Gruenert | PRC | Issue | Broken Radiation Interlock 
 Beam
 was down for all beamlines due to a broken
 radiation interlock in the SPB/SFX experimental
 |   |  | 203 | 23 Nov 2024, 07:09 | Raphael de Wijn | SPB | Shift end | End of in-house 8496
 
 X-ray
 |  |  | 202 | 23 Nov 2024, 00:48 | Jan Gruenert | PRC | Issue | Broken Bridges 
 Around 21h20 the
 XPD group notices that several karabo-to-DOOCS
 bridges are broken.
 |  |  | 201 | 23 Nov 2024, 00:36 | Jan Gruenert | PRC | Issue | 20h16: beam down in all beamlines due to a gun problem
 20h50: x-ray beams are back
 |   |  | 200 | 15 Nov 2024, 10:50 | Frederik Wolff-Fabris | PRC | Issue | SA2 cell#5 undulator segment moved at ~09:45AM Fri to 25mm without aparent reason and
 undulator experts need a ZZ to exchange power
 |  |  | 199 | 12 Nov 2024, 10:07 | Frederik Wolff-Fabris | PRC | Issue | - While FEL IMG with YAG screen was
 inserted in SA1, EPS/MPS was not limited
 to the expected 2 bunches, but to 30
 |   |  | 198 | 04 Nov 2024, 15:07 | Frederik Wolff-Fabris | XO | SA2 status | Dear MID colleagues, Svitozar (PRC), Bolko and Shan (RCs),
 This morning we faced the situation
 |  |  | 197 | 03 Nov 2024, 00:00 | Raphael de Wijn | SPB | Shift summary | X-ray delivery 
 12.5 keV,
 ~1.6 mJ
 |  |  | 196 | 31 Oct 2024, 02:43 | Ulrike Boesenberg | MID | Shift summary | 12.389keV, HXRSS, 1-400+ bunches, 450uJ 
 
 Seeding alignment
 Beamline
 alignment (Mirror + foccussing)
 Measured
 |  |  | 195 | 28 Oct 2024, 09:58 | Peter Zalden | FXE | SA1 status | This is to report some findings during operation that should be looked into (mostly
 to avoid in the future, because both negatively
 |     |  | 194 | 25 Oct 2024, 05:51 | Chan Kim | SPB | Shift summary | X-ray delivery 
 12.4 keV, ~1.4 mJ
 
 
 |  |  | 193 | 24 Oct 2024, 06:51 | Chan Kim | SPB | Shift summary | X-ray delivery
 
 12.4 keV, ~1.4 mJ
 
 Achievements/Observations
 |  |  | 192 | 07 Oct 2024, 16:34 | Naresh Kujala | PRC | Status | Desy Laser group has fixed the issue about the laser Synchronization.
 
 https://ttfinfo.desy.de/XFELelog/show.jsp?dir=/2024/41/07.10_M&pos=2024-10-07T14:51:12
 |  |  | 191 | 07 Oct 2024, 15:15 | Naresh Kujala | PRC | Issue | 14:40hr 
 FXE and HED reported the laser
 synchronization issue. Informed to Machine
 |  |  | 190 | 01 Oct 2024, 02:39 | Tokushi Sato | SPB | Shift summary | X-ray delivery 
 6 keV, ~2.8 mJ, continuous
 beam drift in both direction
 |  |  | 189 | 30 Sep 2024, 01:50 | Jörg Hallmann | MID | Shift summary | 01:49 
 |  |  | 188 | 30 Sep 2024, 01:13 | Chan Kim | SPB | Shift summary | **X-ray delivery** 
 - 6 keV, ~2.8 mJ, continuous beam
 drift in vertical direction (both XTD2 &
 |  |  | 187 | 29 Sep 2024, 22:29 | Chan Kim | SPB | Stability Issue | X-ray beam is continuously drifting in the vertical direction (XTD9_XGM)
 It affects our NKB focus and focused
 |    |  | 186 | 29 Sep 2024, 12:13 | Jan Gruenert | PRC | Status | Beam is back. Current status: 
 SASE1 (SPB/SFX)
 
 
 2.72
 mJ, 352 bunches/train, 6 keV
 
 
 SASE2 (MID)
 
 
 880 uJ,
 |   |  | 185 | 29 Sep 2024, 11:42 | Jan Gruenert | PRC | Issue | A2 failure - downtime 
 The machine
 / RC informs (11h22) that there is an issue
 with the accelerator module A2 (first module
 |  |  |