Group Selection Page HELP Controls Group Data Analysis Group ITDM WP76 DET Vacuum EEE WP78 FXE SPB MID HED SQS SXP Sample Environment Operation PSPO XO TS Migrated2Zulip
OPERATION-2025 OPERATION-2024 OPERATION-2023 OPERATION-2022 OPERATION-2021 OPERATION-2020 OPERATION-2019 SASE1-2018 SASE1-2017 Experiment data
  OPERATION-2023 logbook, Contact: F.Wolff-Fabris, A.Galler, L.Samoylova, H.Sinn, Page 10 of 24  Not logged in ELOG logo
ID Date Author Group Subjectdown Text Attachments
  222   03 Jun 2023, 23:40 Romain LetrunSPBShift summaryX-ray delivery


10.65 keV, up to 339 pulses
at 1.13 MHz, 1.6-1.8 mJ.
12.4
  
  223   04 Jun 2023, 14:53 Konopkova ZuzanaHEDShift summarybeam parameters: 20 keV, 300 uJ, 352 pulses


continuation of user programe.
Machine
performance very good for trying the 20 keV
  
  224   04 Jun 2023, 21:17 Romain LetrunSPBShift summaryX-ray delivery


12.2-12.45 keV, up to 339
pulses at 1.13 MHz, 0.8-1.2 mJ.
Couple
  
  234   09 Jun 2023, 02:22 Ulrike BoesenbergMIDShift summary*Vacuum issues: There seems to be a leak
in the arm nr. 6 (2.4mm CVD Diamond). This
has escalated to trip several times the vacuum
  
  235   09 Jun 2023, 07:05 Adam RoundSPBShift summaryStaff: DZ, AR, MK

X-ray delivery


12.42 keV 169 pulses for
  
  239   10 Jun 2023, 00:39 Ulrike BoesenbergMIDShift summary* Data collection of vycor and glass samples
in SAXS geometry until 9am

* Successful intervention on SA2_XTD1_ATT
  
  240   10 Jun 2023, 06:55 Chan KimSPBShift summaryX-ray delivery


12.42 keV, 0.8 mJ/pulse,
stable delivery


Optical
  
  244   11 Jun 2023, 02:08 Ulrike BoesenbergMIDShift summary* First half of the day was used to optimize
seeding performance
* Cryo issues started at 6 pm; were
  
  246   11 Jun 2023, 07:28 Chan KimSPBShift summaryX-ray delivery


12.42 keV, 0.65 mJ/pulse,
low pulse energy but mostly stable delivery


Optical
  
  249   12 Jun 2023, 02:01 Ulrike BoesenbergMIDShift summary

*Some more tuning of HXRSS and
focus optimization in the morning.
  
  250   12 Jun 2023, 07:16 Chan KimSPBShift summaryX-ray delivery


12.42 keV, stable delivery
with slightly less than 1.0 mJ/pulse (~0.95
  
  253   13 Jun 2023, 23:08 Konopkova ZuzanaHEDShift summarybeam: 18 keV, 352 pulses, ~200 uJ per pulse

achievements:


AGIPD timing scans, AGIPD
  
  254   15 Jun 2023, 06:41 Konopkova ZuzanaHEDShift summary18 keV, 150 uJ per pulse, 2.2 MHz


continuing user program
proposal 3285
X-ray heating and
  
  255   15 Jun 2023, 23:08 Johan BieleckiSPBShift summaryX-ray delivery


12.42 keV, stable delivery
in single pulse mode with 1.9 mJ/pulse


Optical
  
  258   17 Jun 2023, 07:27 Konopkova ZuzanaHEDShift summaryBeam 18 keV, 0.5 MHz, long trains up to
~280 pulses


change setup to dynamic
  
  261   19 Jun 2023, 05:34 Konopkova ZuzanaHEDShift summary
concluded user experiment on dynamically
compressed water
long train operation
worked relatively stable with no major interuptions
  
  281   30 Jul 2023, 02:02 Ulrike BoesenbergMIDShift summary9.3 keV, 1-35pulses, stable delivery ~600uJ
*General alignment of MID branch to
the DES
  
  283   30 Jul 2023, 23:06 Ulrike BoesenbergMIDShift summary9 and 10keV beam, up to 30 bunches, significant
drop in intensity in the morning and in the
evening.
  
  288   05 Aug 2023, 08:20 Romain LetrunSPBShift summaryX-ray delivery


9.3 keV, 1-202 pulses at
1.13 MHz, 1.9-2.1 mJ.
Overall
  
  289   05 Aug 2023, 15:33 Ben, JustineSCSShift summaryAchievements


Measured XAS and RIXS from
NdNiO3 test sample at 230 K


Plan
  
ELOG V3.1.4-7c3fd00