ID |
Date |
Author |
Group |
Subject |
Text |
 |
222
|
03 Jun 2023, 23:40 |
Romain Letrun | SPB | Shift summary | X-ray delivery
10.65 keV, up to 339 pulses
at 1.13 MHz, 1.6-1.8 mJ.
12.4 |
|
223
|
04 Jun 2023, 14:53 |
Konopkova Zuzana | HED | Shift summary | beam parameters: 20 keV, 300 uJ, 352 pulses
continuation of user programe.
Machine
performance very good for trying the 20 keV |
|
224
|
04 Jun 2023, 21:17 |
Romain Letrun | SPB | Shift summary | X-ray delivery
12.2-12.45 keV, up to 339
pulses at 1.13 MHz, 0.8-1.2 mJ.
Couple |
|
234
|
09 Jun 2023, 02:22 |
Ulrike Boesenberg | MID | Shift summary | *Vacuum issues: There seems to be a leak
in the arm nr. 6 (2.4mm CVD Diamond). This
has escalated to trip several times the vacuum |
|
235
|
09 Jun 2023, 07:05 |
Adam Round | SPB | Shift summary | Staff: DZ, AR, MK
X-ray delivery
12.42 keV 169 pulses for |
|
239
|
10 Jun 2023, 00:39 |
Ulrike Boesenberg | MID | Shift summary | * Data collection of vycor and glass samples
in SAXS geometry until 9am
* Successful intervention on SA2_XTD1_ATT |
|
240
|
10 Jun 2023, 06:55 |
Chan Kim | SPB | Shift summary | X-ray delivery
12.42 keV, 0.8 mJ/pulse,
stable delivery
Optical |
|
244
|
11 Jun 2023, 02:08 |
Ulrike Boesenberg | MID | Shift summary | * First half of the day was used to optimize
seeding performance
* Cryo issues started at 6 pm; were |
|
246
|
11 Jun 2023, 07:28 |
Chan Kim | SPB | Shift summary | X-ray delivery
12.42 keV, 0.65 mJ/pulse,
low pulse energy but mostly stable delivery
Optical |
|
249
|
12 Jun 2023, 02:01 |
Ulrike Boesenberg | MID | Shift summary |
*Some more tuning of HXRSS and
focus optimization in the morning. |
|
250
|
12 Jun 2023, 07:16 |
Chan Kim | SPB | Shift summary | X-ray delivery
12.42 keV, stable delivery
with slightly less than 1.0 mJ/pulse (~0.95 |
|
253
|
13 Jun 2023, 23:08 |
Konopkova Zuzana | HED | Shift summary | beam: 18 keV, 352 pulses, ~200 uJ per pulse
achievements:
AGIPD timing scans, AGIPD |
|
254
|
15 Jun 2023, 06:41 |
Konopkova Zuzana | HED | Shift summary | 18 keV, 150 uJ per pulse, 2.2 MHz
continuing user program
proposal 3285
X-ray heating and |
|
255
|
15 Jun 2023, 23:08 |
Johan Bielecki | SPB | Shift summary | X-ray delivery
12.42 keV, stable delivery
in single pulse mode with 1.9 mJ/pulse
Optical |
|
258
|
17 Jun 2023, 07:27 |
Konopkova Zuzana | HED | Shift summary | Beam 18 keV, 0.5 MHz, long trains up to
~280 pulses
change setup to dynamic |
|
261
|
19 Jun 2023, 05:34 |
Konopkova Zuzana | HED | Shift summary |
concluded user experiment on dynamically
compressed water
long train operation
worked relatively stable with no major interuptions |
|
281
|
30 Jul 2023, 02:02 |
Ulrike Boesenberg | MID | Shift summary | 9.3 keV, 1-35pulses, stable delivery ~600uJ
*General alignment of MID branch to
the DES |
|
283
|
30 Jul 2023, 23:06 |
Ulrike Boesenberg | MID | Shift summary | 9 and 10keV beam, up to 30 bunches, significant
drop in intensity in the morning and in the
evening. |
|
288
|
05 Aug 2023, 08:20 |
Romain Letrun | SPB | Shift summary | X-ray delivery
9.3 keV, 1-202 pulses at
1.13 MHz, 1.9-2.1 mJ.
Overall |
|
289
|
05 Aug 2023, 15:33 |
Ben, Justine | SCS | Shift summary | Achievements
Measured XAS and RIXS from
NdNiO3 test sample at 230 K
Plan |
|
|