CAS OCD: Support requested starting SA1_XTD2_MCP/ADC/MCP3, posted by David Hickin on 21 May 2017, 15:02
|
Contacted at home 21:30 19.05. Request for support starting SA1_XTD2_MCP/CDC/MCP3 on cppServer/sa1_utca_17.
Located project and device server. Attempted to start SA1_XTD2_MCP/CDC/MCP3. Issue was missing fastAdc plugin. Found info on sa1_utca_17 in commissioning
guidelines: say server is exflutc106. |
CAS OCD: Support requested starting SA1_XTD2_MCP/ADC/MCP3, posted by David Hickin on 21 May 2017, 16:28
|
David Hickin wrote:
Contacted at home 21:30 19.05. Request for support starting SA1_XTD2_MCP/CDC/MCP3 on cppServer/sa1_utca_17. |
CAS OCD: Support requested starting SA1_XTD2_MCP/ADC/MCP3, posted by David Hickin on 21 May 2017, 16:29
|
David Hickin wrote:
|
CAS OCD: Support requested starting SA1_XTD2_MCP/ADC/MCP3, posted by David Hickin on 21 May 2017, 16:50
|
David Hickin wrote:
|
AE OCD Mai 19 -- Mai 22, posted by Nicola Coppola on 19 May 2017, 15:42
|
AE on call service:
Contact person:
Nicola Coppola |
Update of Instrument component priority list , posted by Monica Aresté on 19 May 2017, 12:46
|
Normal
0
21
false
false
false
|
Status and plans after SASE1 Readiness Meeting, posted by Tobias Haas on 19 May 2017, 11:30
|
General (T. Haas)
Due to problems with interlock cabling the approval date with the TÜV on 1 June has been cancelled
The MB, SASE1
Instruments, AE, CAS and PSPO met yesterday and agreed that in view of the schedule risks with technical commissioning the focus of the next weeks |
Motion loop, posted by NEREA JARDON on 18 May 2017, 16:36
|
Dear all,
I have already contacted Andreas Koch, and Alessandro has contacted the BKR in order to do a new update of the motion loop because of one small
bug detected. |
Imager status, posted by Andreas Koch on 18 May 2017, 16:32
|
After the update of the PLC firmware, the imagers are in following status:
SR: auto gain off seems to work, correct image, screens are out. Beamview just crashed, I asked Alessandro and Dennis to have a look.
Pop-In: Everything fine. |
OCD AE Group, posted by NEREA JARDON on 18 May 2017, 15:30
|
Dear all,
The OCD AE numbers for the following days will be: |
Motion loop, posted by NEREA JARDON on 18 May 2017, 13:38
|
The Motion loop is again up and running.
Thank you |
Motion loop, posted by NEREA JARDON on 18 May 2017, 12:18
|
Dear all,
The motion loop will be updated in 5 minutes. The IMGs are already in safe state, please do not operate nothing. I have already contacted the control
room and Harald Sinn as representative of the commissioning team. |
Vacuum issue in XTD9 during cycling of PLC loop yesterday, posted by Jan Grünert on 18 May 2017, 11:57
|
During the usual recovery procedure after the planned and announced cycling of the SASE1 VAC loop yesterday, we observed a serious mistake by somebody:
The gatevalve(s) of the DP section in XTD9 were opened before the related turbo pumps were (fully) operating. |
Motion loop, posted by NEREA JARDON on 17 May 2017, 17:51
|
Dear all,
The Motion loop will be updated tomorrow due to some delays during the day. It will include the MCP XTD2 X movement.
Thank you and sorry for the inconvenience. |
CAS OCD, posted by Sergey Esenov on 17 May 2017, 16:17
|
CAS on call service for the night 98057 |
Vacuum Loop, posted by NEREA JARDON on 17 May 2017, 13:57
|
Dear all,
The Vacuum Loop will be updated now. You will be able to connect to it again in few minutes.
Thank you, |
Status and Plans after 09:30 meeting, posted by Tobias Haas on 17 May 2017, 11:55
|
Interlock in XTD10 is broken today and tunnel is open until 15:00
General:
Unfortunately, info on access to XTD10 came too late for Vacuum group to organise the work in XTD10
Technical issues and |
Reminder S1R Dispatch at 09:30 today in front of MCR (Mockup Control Room), posted by Tobias Haas on 17 May 2017, 08:52
|
|
cycling of SASE1 tunnel VAC loop (if needed), posted by Jan Grünert on 16 May 2017, 22:54
|
If the recycling of the VAC loop for XTD2+9 is required as I understand from AE,
tomorrow would be a good time because there is no beam (in SASE1 until at least 15h).
After about 10h30 would be ok for me. |
Request for imager checks, posted by Andreas Koch on 16 May 2017, 15:59
|
Since tomorrow there is no beam I want to use the time for some checks of the imagers in XTD2. Please, let the motion loop up if possible until 10 am,
otherwise let me know. |
CAS On-Call Duty Planning (Until 11/06), posted by Hugo Silva Santos on 16 May 2017, 14:55
|
Dear All,
I would like to share the CAS OCD Planning
until 11/06: |
Motion loop, posted by NEREA JARDON on 16 May 2017, 13:50
|
Dear all,
Due to local test needed in Rack 1.18 for the Motion loop, it will be interrupted only in Rack 1.18 XTD9 from now till tests finish. It will not
affect any other part of the Motion loop. |
OCD CAS, posted by Thomas Michelat on 15 May 2017, 22:17
|
Dear all,
The OCD number for tonight (15/05) for the CAS group is 98053.
thanks |