ID Date Author Groupdown Subject Text Attachments
  28   25 Feb 2025, 02:41 Jayanath KoliyaduSPBShift summaryX-ray delivery
-15 keV with Hirex monitoring, 0.5
mJ/pulse, 202 pulses/train at 0.56 MHz pulse
  
  29   27 Feb 2025, 07:02 Tokushi SatoSPBShift summaryX-ray delivery

    up to 202/352
pulses per train (~0.8 mJ pulse energy)@13.4
  
  30   28 Feb 2025, 06:57 Tokushi SatoSPBShift summaryX-ray delivery

    up to 202/352
pulses per train (~0.8 mJ pulse energy)@13.4
  
  31   01 Mar 2025, 06:56 Tokushi SatoSPBShift summaryX-ray delivery

    up to 202/352
pulses per train (~0.8 mJ pulse energy)@13.4
  
  33   02 Mar 2025, 06:56 Tokushi SatoSPBShift summaryX-ray delivery

    up to 175 pulses
per train (~1 mJ pulse energy)@13.4 keV,
  
  34   03 Mar 2025, 07:05 Tokushi SatoSPBShift summaryX-ray delivery

    up to 188 pulses
per train (~1 mJ pulse energy)@13.4 keV,
  
  35   04 Mar 2025, 07:05 Tokushi SatoSPBShift summaryX-ray delivery

    up to 188/352
pulses per train (~1 mJ pulse energy)@13.4
  
  36   12 Mar 2025, 23:14 Raphael de WijnSPBShift summary
SPB/SFX
shift summary user experiment 6933 (setup
day)
  
  38   17 Mar 2025, 06:51 Romain LetrunSPBIssueThe status of the FXE shutter in the Public
status display DOOCS panel is incorrect.
Here appears as opened, when it is actually
 Screenshot_from_2025-03-17_06-45-52.png 
  39   27 Mar 2025, 22:57 Tokushi SatoSPBShift end**X-ray delivery:**
* 16 keV, ~upto 1 mJ, 160 pulses
**Optical Laser:**
  
  46   09 Apr 2025, 22:46 Tokushi SatoSPBShift summaryX-ray delivery:

20 keV, ~ 400 uJ, 128 pulses, stable
delivery 
  
  47   10 Apr 2025, 23:17 Tokushi SatoSPBShift summaryX-ray delivery:

20 keV, ~ 400 uJ, 128 pulses, stable
delivery 
  
  48   11 Apr 2025, 23:14 Tokushi SatoSPBShift summaryX-ray delivery:

20 keV, ~ 400 uJ, 246 pulses,
stable delivery
  
  49   12 Apr 2025, 23:15 Tokushi SatoSPBShift summaryX-ray delivery:

20 keV, ~ 500 uJ, 246 pulses, stable
delivery
  
  50   13 Apr 2025, 22:55 Tokushi SatoSPBShift summaryStaff: PV, TS, JK, FK, + users

X-ray delivery:

20 keV, ~ 300-400 uJ, 250 pulses,
  
  52   14 Apr 2025, 23:08 Tokushi SatoSPBShift summaryX-ray delivery:

20 keV,  250-400 uJ, 250 pulses,
stable delivery
  
  53   17 Apr 2025, 01:39 Chan KimSPBShift summaryX-ray delivery


18.8 keV, 260 uJ pulse
energy


Optical
  
  54   24 Apr 2025, 06:56 Jayanath KoliyaduSPBShift summaryX-ray delivery:

10 keV, ~ 900 uJ, 128 pulses, tuning
was needed for few hours
  
  56   25 Apr 2025, 06:48 Tokushi SatoSPBShift summaryX-ray delivery:

10 keV, ~ 850 uJ, 128 pulses, tuning
was needed for 1 hour 
  
  57   26 Apr 2025, 06:55 Tokushi SatoSPBShift summaryStaff: PV, TS, JK + external collaborators 

X-ray delivery:

10 keV, ~ 800 uJ, 128 pulses, tuning
  