Entry   Issue, posted by Rebecca Boll on 10 May 2024, 00:04 
our pp laser experienced timing jumps by 18 ns today. this happened for the first time at ~7:30 in the morning without us noticing and a couple of more
times during the morning. we realized it at 15:30 due to the fact that the signal on our pulse arrival monitor (X-ray/laser cross correlator downstream
of the experiment) disappeared. we spent some time to investigate it, until we also see this jump in two different photodiodes different triggers (oscilloscope
Entry   Issue, posted by Rebecca Boll on 25 May 2024, 02:38 Run_177_vs_247.pngScreenshot_from_2024-05-25_00-44-46.pngScreenshot_from_2024-05-25_01-03-29.pngScreenshot_from_2024-05-25_01-36-54.png
Today in the afternoon, SASE1 was tuned (a description of the activities in att 4). We now realize that this has in some form changed the SQS pulse parameters.

att 1 shows ion spectra recorded under nominally the same photon parameters before (run 177) and after (run 247)

it's also visible in the history of the SASE viewer that the behavior of the SASE3 pulse energy is different before and after 15:45, which
Entry   Issue, posted by Raśl Villanueva-Guerrero on 08 May 2024, 13:51 image_2024-05-08_135756593.pngimage_2024-05-08_140027070.pngimage_2024-05-08_140101131.pngimage_2024-05-08_140228955.png
Dear all,

Due to a probable issue at the SA1 Transmissive imager, the "OUT" and "YAG" position indication signals seems to be not responsive.

After the FXE team noticed that MODE S was interlocked, the root cause has been narrowed down to this component. Later, further investigation
Entry   Issue, posted by Raśl Villanueva-Guerrero on 25 Sep 2024, 10:12 
Issue with SA3 Gas attenuator (SA3_XTD10_GATT) - SOLVED

Dear all,

after the reported issue by SQS colleagues regarding the impossibility to inject Argon, and after a first remote evaluation, we (VAC) have entered
XTD10 to assess the status and verify the most probable working hypothesis: a manual valve in the supply line was closed (otherwise as expected). Joshua
Entry   Shift summary, posted by Raphael de Wijn on 04 Mar 2024, 06:52 

X-ray delivery


10 keV, up to 128 pulses with custom bunch pattern, 1.6-2.0 mJ


Optical laser delivery


NA


Achievements/Observations
Entry   Shift summary, posted by Raphael de Wijn on 21 Mar 2024, 06:33 
X-ray delivery
- 9.3 keV, >3 mJ/pulse, stable delivery 

Optical laser delivery
Entry   Shift summary, posted by Raphael de Wijn on 22 Mar 2024, 06:35 
X-ray delivery
- 9.3 keV, >3 mJ/pulse, beam down around 30min

Optical laser delivery
Entry   Shift summary, posted by Raphael de Wijn on 04 Apr 2024, 06:48 
In-house/commissioning beam time summary night 1

X-ray delivery:
12.7 keV, up to 208 pulses at 1.1MHz, 1.1-1.5 mJ
Entry   Shift summary, posted by Raphael de Wijn on 05 Apr 2024, 07:14 
In-house/commissioning beam time summary night 2

X-ray delivery:
12.7 keV, up to 288 pulses at 1.1MHz, ~1.2 mJ
Entry   Shift summary, posted by Raphael de Wijn on 06 Apr 2024, 07:06 
Staff: MS, RB, PS, RdW

In-house/commissioning beam time summary night 3

X-ray delivery:
Entry   Shift summary, posted by Raphael de Wijn on 07 Apr 2024, 07:04 
In-house/commissioning beam time summary night 4

X-ray delivery:
12.7 keV, up to 128 pulses at 0.5MHz, ~1.3 mJ, one very short beam down.
Entry   Shift summary, posted by Raphael de Wijn on 22 Apr 2024, 00:06 

User beamtime 5157 day 5

X-ray delivery:


21 keV, ~400 uJ


Optical Laser:
Entry   Shift summary, posted by Raphael de Wijn on 22 Apr 2024, 23:26 
End of User beamtime 5157


X-ray delivery:


21 keV, ~500 uJ; stable delivery


Optical Laser:
Entry   Shift summary, posted by Raphael de Wijn on 11 Aug 2024, 23:07 
X-ray delivery

11.56 keV 202 pulses @0.5 MHz, ~1.0 mJ

some downtime due to fire alarm in the tunnel
Entry   Shift summary, posted by Raphael de Wijn on 12 Aug 2024, 23:47 

X-ray delivery

11.56 keV, 202 pulses @0.5 MHz, ~0.9 mJ, stable delivery

Optical laser delivery
Entry   Shift summary, posted by Raphael de Wijn on 21 Aug 2024, 23:34 
X-ray delivery

12.40 - 12.82 keV, ~1.1 mJ

Optical laser delivery
Entry   Shift summary, posted by Raphael de Wijn on 22 Aug 2024, 23:15 
X-ray delivery

12.40 - 12.82 keV, ~1.1 mJ

Optical laser delivery
Entry   Shift summary, posted by Raphael de Wijn on 14 Sep 2024, 23:13 
X-ray delivery
8.951 keV, 1.2 mJ up to 30pulses at 113 kHz

Achievements/Observations
Entry   Shift summary, posted by Raphael de Wijn on 15 Sep 2024, 23:12 
X-ray delivery
8.951 keV, 1.6 mJ up to 16 pulses at 113 kHz

Achievements/Observations
Entry   Shift summary, posted by Raphael de Wijn on 03 Nov 2024, 00:00 
X-ray delivery

12.5 keV, ~1.6 mJ

Achievements/Observations: