Shift summary, posted by Chan Kim on 27 Apr 2023, 00:07
|
SPB/SFX User Proposal 3333 Shift 2 Summary
X-ray delivery
9.3 keV, 1.7 mJ, 202 pulses @ 564 kHz |
Shift summary, posted by Richard Bean on 27 Apr 2023, 23:33
|
SPB/SFX PCS user proposals (day 1)
X-ray delivery
9.3 keV, 1600 uJ/ pulse
Achievements/Observations |
Shift summary, posted by Richard Bean on 28 Apr 2023, 21:55
|
SPB/SFX In-house research 4978
X-ray delivery
9.3 keV 202 pulses / train, relatively stable intensity 1.9 mJ / pulse, some decrease in intensity across train
Optical |
Shift summary, posted by Richard Bean on 29 Apr 2023, 22:00
|
SPB/SFX In-house research 4978 shift 2
X-ray delivery
9.3 keV 202 pulses / train, relatively stable intensity 2.0 mJ / pulse at start of train, ~30% decrease in intensity across train
BKR |
Shift summary, posted by Raphael de Wijn on 30 Apr 2023, 21:59
|
SPB/SFX In-house research 4978 shift 3 - end
X-ray delivery
9.3 keV 352 pulses / train, relatively stable intensity ~1.9 mJ / pulse
beam down ~30 min
Optical |
Shift summary, posted by Tokushi Sato on 04 May 2023, 06:41
|
X-ray delivery
12.4 keV 200 pulses / train, relatively stable intensity ~0.8 mJ / pulse
took some time in changing X-ray energy (from 19.16
keV to 12.4 keV)
Optical laser delivery |
Issue, posted by Tokushi Sato on 05 May 2023, 00:50
|
Laser synchronization is gone, unlocked from 04.05.2023, 22.47. E-mail was sent to lbsync-expert@desy.de and c.c. to las-op@xfel.eu. |
Shift summary, posted by Tokushi Sato on 05 May 2023, 06:44
|
X-ray delivery
12.4 keV 200 pulses / train, relatively stable intensity ~0.8 mJ / pulse
Optical laser delivery
420 nm PP laser
ns laser for jet imaging
Achievements/Observations |
Shift summary, posted by Tokushi Sato on 06 May 2023, 06:55
|
X-ray delivery
12.4 keV 200 pulses / train, relatively stable intensity ~1.2 mJ / pulse
Optical laser delivery
420 nm PP laser
ns laser for jet imaging
Achievements/Observations |
Shift summary, posted by Romain Letrun on 09 May 2023, 23:09
|
X-ray delivery
9.3 keV, 1.8 mJ, 202 pulses most fo the day. Pronounced (~30-40%) slope across the train.
Pointing initially far off the reference
crosshair. One hour required at the start of the shift to go to 9.3 keV and align the beam to the crosshair.
Optical laser delivery |
Shift summary, posted by Romain Letrun on 10 May 2023, 23:23
|
X-ray delivery
9.3 keV, 1.6 mJ, 202 pulses msot of the day.
Slope across the train reduced comapred to yesterday, now about 25%.
Changes
in number of pulses in SASE3 not always automatically picked-up by kickers adaptation and requiring a nudge from BKR to restore performances.
Beam |
Shift summary, posted by Romain Letrun on 11 May 2023, 23:48
|
X-ray delivery
9.3 keV, 1.4-1.8 mJ and 12 keV, 1.1 mJ. 202 pulses most of the day.
Reduced slope after afternoon tuning, down to 20%.
Change
to 12 keV with file prepared earlier this week did not work (no lasing). Tuning to 12 keV took 40 minutes.
30 minutes downtime in the morning.
Optical |
Shift summary, posted by Romain Letrun on 12 May 2023, 23:21
|
X-ray delivery
9.3 keV, 1.8 mJ, 202 pulses most of the day.
Attempted tuning to 14.8 keV during the first hour fo the shift did not work
out. More time will be spent tomorrow morning tuning to that photon energy.
Overall stable delivery. Only a magnet failure at 20:25 resulted |
Shift summary, posted by Tokushi Sato on 18 May 2023, 18:41
|
X-ray delivery
9.3 keV, ~1 mJ, 1-30 pulses, stable delivery
Optical laser delivery
None
Achievements/Observations |
Shift summary, posted by Tokushi Sato on 19 May 2023, 18:39
|
X-ray delivery
9.3 keV, 800 uJ, 1-200 pulses, stable delivery
Optical laser delivery
None
Achievements/Observations |
Shift summary, posted by Tokushi Sato on 21 May 2023, 18:38
|
X-ray delivery
9.3 keV, 800 uJ, 1-200 pulses, stable delivery
Optical laser delivery
None
Achievements/Observations |
Shift summary, posted by Tokushi Sato on 25 May 2023, 06:35
|
X-ray delivery
10.7 keV, 1.2 mJ, 1-200 pulses, stable delivery
Optical laser delivery
None
Achievements/Observations |
Shift summary, posted by Romain Letrun on 30 May 2023, 23:02
|
X-ray delivery
10.7 keV, up to 339 pulses at 1.1 MHz.
Large slope through the train, up to 70% with 339 bunches. BKR was not able to find
the cause so far, we agreed to pursue this further tomorrow.
Achievements/Observations |
Shift summary, posted by Romain Letrun on 31 May 2023, 23:15
|
X-ray delivery
10.65 keV, 128 pulses at 1.13 MHz and 16 pusles at 141 kHz.
Slope reduced at the start of the shift. Approximately 20% slope
after that with the patterns used for data collection today.
Optical laser delivery |
Shift summary, posted by Romain Letrun on 01 Jun 2023, 23:27
|
X-ray delivery
10.65 keV, 128 pulses at 1.13 MHz and 16 pusles at 141 kHz.
Overall stable delivery.
Optical laser
delivery |