Group Selection Page
HELP
Controls Group
ITDM
DET
Vacuum
WP78
FXE
SPB
HED
SQS
SXP
Sample Environment
PSPO
XO
TS
Migrated2Zulip
Archived2PDF
MigratedByGroup
|
|
SCS
Photon Commissioning Team
XRO
DOC
WP74
MID
XO_mig
XO_Operation
|
|
Technical integration and coordination
|
| Technical integration and coordination logbook, Contact: A. Violante, G. Wellenreuther |
Not logged in |
 |
|
|
Message ID: 606
Entry time: 23 Apr 2025, 09:27
|
| Author: |
Andreas Galler |
| Location: |
General |
| Severity: |
Information |
| Subject: |
Notes XO Integration Meeting 23.04.2025 |
|
|
General Announcement:
CTRL:
- guiserver at MID
- backbone services moved to a new machine --> should mitigate the issue
DA:
- all fine at DA and so far quiet on DOC
EEE:
VAC:
XPD:
DET:
- DSSC2
- very successful from Thursday 15:00, big thanks to all groups involved recovering the undualtros to make this posssible.
ITDM:
XRO:
LAS:
- slight problem with fastADC cards in SA3 --> EEE is informed
UNSYS:
- SA3 undulator last week
- communication issue through fiber optics
- mitigation included switching from multimode to singlemode communication, including changing EtherCAT terminal and reconfiguring the PLC
- cell 12 damaged linear encoder SA3
-
SPB/SFX:
FXE:
MID:
HED:
SCS:
SQS:
SXP:
DRC
PRC
AOB:
- problem at FXE wiht an MDL of the Mono
- MDL was in unknown state