Group Selection Page HELP DOC Controls Group Data Analysis Group ITDM WP76 DET Vacuum XRO EEE WP78 WP74 FXE SCS SPB MID HED SQS SXP Sample Environment Photon Commissioning Team Operation PSPO XO TS
Technical integration and coordination SASE1 Status and SASE3 Readiness
  Technical integration and coordination logbook, Contact: A. Violante, G. Wellenreuther  Not logged in ELOG logo
Message ID: 324     Entry time: 11 May 2022, 10:02
Author: Frederik Wolff-Fabris 
Location: General 
Severity: Information 
Subject: Notes XO Integration Meeting 11.05.2022 
General Announcement:
- The accelerator is currently down. An electrical power issue lead to a cryo failure at 08:45AM and both cold and warm compressors went down. 
The expected cryo OK shall come in the afternoon and by 15:30 we will have further information.

CTRL:
- Nothing to report.

DA:
- Nothing to report.

EEE:
- Nothing to report.

VAC:
- Incident in MID branch/SA2 last evening with the V0 valve being closed: VAC received automatic message with spike around the CRL2 was detected, then closing the V0 valve. Solved in 5 mins. 
Please report to VAC group (08:42PM) when such incidents happen. Reason behind this even is still unclear.

XPD:
- Nothing to add.

DET:
- Nothing to report.

ITDM: 
- A Change in configuration of run controllers for the DAQ may profit today as machine is down. ITDM will discuss with groups and inform accordingly. 
To be done in tunnels, laser, 5 instruments apart of SPB/SFX. One has to reload projects afterwards.

XRO:
- Nothing to report.

LAS:
- Nothing to report.

UNSYS:
- Apple-X: massive losses of encoders were found and the FD program is cancelled. A ZZ will be done today.
- Heidenheim linear encoders need to be replaced, quote is placed but not sure if it happens in summer maintenance.

SPB:
- Reconfiguring the instrument for the weekend.

FXE:
- Problem with XGMd: under work by Theo and Finni.

MID:
- It has now the PicoAmpmeter; in touch with EEE and CTRL.

HED:
- Monday long pulse train test: seems to be fine; also beam pointing stability went fine for HED.
- XRO was working with mirrors: Mikako M. says that Maurizio M. will address with HED the tests of vertical positions.

SCS:
- Nothing to report.

SQS:
- Nothing to report.
ELOG V3.1.4-7c3fd00