Group Selection Page HELP DOC Controls Group Data Analysis Group ITDM WP76 DET Vacuum XRO EEE WP78 WP74 FXE SCS SPB MID HED SQS SXP Sample Environment Photon Commissioning Team Operation PSPO XO TS
Technical integration and coordination SASE1 Status and SASE3 Readiness
  Technical integration and coordination logbook, Contact: A. Violante, G. Wellenreuther  Not logged in ELOG logo
Message ID: 312     Entry time: 28 Mar 2022, 10:09
Author: Frederik Wolff-Fabris 
Location: General 
Severity: Information 
Subject: Notes XO Integration Meeting 28.03.2022 
General Announcement and A.O.B.:
- BTM @ FXE was triggered on Saturday afternoon and only PRC was available to come onsite and fix the issue. Different procedures will be proposed to be put in place.
- SRI conference starts this week.

CTRL:
- Issue with data loggers last week: narrowed down to an issue with expected update of Telegraph. This time it caused a trigger in the broker pileup. Solved with help from ITDM.
- Upgrade in tunnels today (already agreed; see last meeting minutes).
- Issue with MID/SPB AGIPD middle layer: requires an upgrade of framework. Currently there is no agreed time with instruments but proposal is to make it on a Monday.

DA:
- Nothing to report.

EEE:
- Busy with FXE pump commissioning.

VAC:
- Nothing to report.
- Martin Dommach, as PRC, reports that energy change in SA1 was not permitted during the weekend (costing many lost shifts in SPB) due to crosstalk with SA3; 
on Saturday an event with BTM monitor in XTD9/FXE shutter happened and brought down machine. SA2 and SA3 was restored after 1 hour and SA1 after 3,5 hours.

XPD:
- Nothing to report.

DET:
- Nothing to report.

ITDM: 
- Nothing to report.

XRO:
- Nothing to report.

LAS:
- Problem with shutter in SQS instrument laser hutch during the weekend: it could continue apart of the error state. Under investigation.

UNSYS:
- Next Monday a ZZ is requested to 1. get phase shifter SA3/cell26 working; 2. Investigate cell 25/SA3 Quad mover (horizontal movement in wrong direction).

SPB:
- Lost shifts due to crosstalk (2 night-shifts on weekend). Apart of that other shifts went well.

FXE:
- Incident on Thursday (LPD motor not working): after restarting it lost motor positions. Stefen H. says that A. Silenzi is preparing a report and updates will follow.

MID:
- Quite good week with small hiccups in data acquisition.

HED:
- HED asks when EEE plans to update uTCA; EEE advices to please contact Bruno F.

SCS:
- Issue with replaced turbo pump: new one enters in error mode after going to 400Hz. SCS is in contact with VAC; to be fixed today.

SQS:
- Nothing to report.
ELOG V3.1.4-7c3fd00