Technical integration and coordination
SASE1 Status and SASE3 Readiness
|
Technical integration and coordination logbook, Contact: A. Violante, G. Wellenreuther |
Not logged in |
|
|
Message ID: 303
Entry time: 23 Feb 2022, 10:30
|
Author: |
Frederik Wolff-Fabris |
Location: |
General |
Severity: |
Information |
Subject: |
Notes XO Integration Meeting 23.02.2022 |
|
|
General Announcement:
- A. Galler reminds instruments and support groups to feel welcome in making regular entries on the Operations-2022 e-log.
CTRL:
- FastX of GATT middle layer devices was updated last Monday; the slowness issue is improved and fixed.
- Analyzing to upgrade the broker pile-up issue at Karabo: probably to be fixed by next Monday.
- On the BAM monitor: few properties were changed in the DOOCS side. Changes are transparent to DAQ and all the data must be able to be stored.
Problem appears when data shall be analyzed and then must be looked to the new DAQ. In case of issues please get in touch with CTRL.
DA:
- Maxwell GPFS access rights bug: patch was deployed on Monday and went successfully.
- Next week there will be an update of calibration (further announcement to be done).
EEE:
- Started installing Coax cables for SXP.
- LBM in MID: EEE contacted Beckhoff and will try to get a fix done still this week.
VAC:
- Nothing to report.
XPD:
- Issues with Desy mobile phones: not all phones were equally affected. Issue seems to be fixed this morning.
- In SA2 the SRA slits were too wide open (probably from tuning times). They were closed yesterday night after users finished work.
- Beam delivery to instruments is running fine and smooth.
DET:
- AGIPD detector at SPB: issue with one of 16 modules not sending data since yesterday. Investigation ongoing with DOC and experts.
Jolanta S.-D. says that this is a new issue which happened twice yesterday and Desy is contacted. An intervention for the hardware during the blue week shall take place. It may be related to electronics
outside detector.
ITDM:
- Issue with "phantom" data appearing at DAQ in SA3 instrument: investigation shows it can't be reproduced; maybe it relates to data arriving earlier. It was only visible at DOOCS devices (Undulators
device). Under further investigation by ITDM.
XRO:
- CRLs in SA2 fixed by ZZ.
LAS:
- Nothing to report.
UNSYS:
- Nothing to report.
SPB:
- Nothing apart of the detector report.
FXE:
- Thanks to CTRL for addressing BAM issue.
MID:
- Thanks for solving CRL2 issue on Monday.
HED:
- Two-color mode working with nice energies. Investigation source shape from undulators with lenses.
SCS:
- Nothing to report.
SQS:
- Not present. |