General Announcement:
- Quick report of yesterday incident of water running down to XHEXP1: a washing machine in the clean room at ground level leaked; the water went down to the SA4/5 area of XHEXP1.
Both ground floor and XHEXP1 floors were wet. The washing machine is taken out of service.
CTRL:
- The ticketing system "control-integration" is working again and can be used.
DA:
- Nothing to report.
EEE:
- Fast electronics announcement: tomorrow late afternoon EEE will apply the fix to DSSC camera to correct train-IDs.
VAC:
- A test on the signal optimization in SA3 vacuum loop was done. VAC found a fix that will be applied during the shutdown (together with CTRL, EEE).
XPD:
- Nothing to report.
DET:
- pnCCD risk analysis: DET says that there is a path to avoid accident again and has been discussed with instrument. The misbehavior of the bottom module is to be investigated and replaced.
ITDM:
- Nothing to report.
XRO:
- Nothing to report.
LAS:
- Improvement of sync system in SA3 laser hutch took place this week. The laser is available to instruments.
UNSYS:
- Nothing to report.
SPB:
- Nothing to report.
FXE:
- Nothing to add.
MID:
- All fine at MID.
HED:
- Nothing to report.
SCS:
- Nothing to report.
SQS:
- Nothing to report. |