Group Selection Page
HELP
DOC
Controls Group
Data Analysis Group
ITDM
WP76
DET
Vacuum
XRO
EEE
WP78
WP74
FXE
SCS
SPB
MID
HED
SQS
SXP
Sample Environment
Photon Commissioning Team
Operation
PSPO
XO
TS
|
Technical integration and coordination
SASE1 Status and SASE3 Readiness
|
Joint Operation and Readiness Logbook, Contact: T.Haas, A. Violante, G. Wellenreuther |
Not logged in |
|
|
Message ID: 381
Entry time: 11 Sep 2017, 10:32
|
Author: |
Tobias Haas |
Location: |
General |
Severity: |
Information |
Subject: |
Status and plans after 09:30 meeting |
|
|
General
- More or less continuous beam delivery over the weekend
- Beam was lost 2 times. Took almost 2h to recover in the second case
- The stability of the machine was poor.
- SPB cannot achieve a good focus and FXE reports sync problems as the timining jumps by 220ns (1 bucket) from train to train
SPB
- Liquid jet could be operated with water for an entire shift
- Images were acquired both with powder samples as well as with the water jet
- A lot of flat field data was taken for AGIPD calibration
- One camera had a problem and CAS was called in
- There is unexpected behaviour with limit switches. Suspicion from CAS: A SW flag might be incorrectly set. A. Silenzi and B. Weinhausen will investigate)
FXE
- As stated above, the timing jumps in machine operation render pump-probe experiments impossible. A way out might be 4.5MHz operation which has other issues
- Need a lot more experience with the new scan tool
- Request is made for training on the configurator tool: ITDM reports that they have set up a script to set the many parameters from stored values
- There is a fundamental problem that the scan tools does not see some parameters available in DOOCs. Hence scanning is not really possible right now.
AE
- There are at least two arms in the XTD2 CRL in error. This requires access. Possibly bundle with the ZZ request of W. Freund
- Two loops in SPB still require update (loops5/12)
- It is not clear why many configuration parameters have to be put back by hand after a loop update. N. Jardon and B. Weinhausen will check
ITDM
- Many tests over the weekend for DAQ of slow data with SPB
- Problems were observed because train IDs were zero
- Also time stamps showed values of many hundred hours ago
- CAS suspects that this might be due to wrong configuration of some devices (use_timeserver flag)
|