Subject:
Status and Schedule after 09:30 meeting
General
Access to tunnel XTD10 ends today around midday and beam is expected back for the instruments on Thursday
SPB
Good progress was made over the weekend with AGIPD. On Saturday first dark images were recorded
Today the detector hybrids are being exchanged (1.0 -> 1.1)
The injector motion system was taken into operation
The SmarACT stages can currently not be tested since some parts are disassembled for final AGIPD installation
FXE
Some loose ends were tied up for LPD
JJXray was here last week and did some more installations, e. g. I0 monitors and alignment of the sample stack
This week Gotthard integration will proceed
Tunnels
The vacuum loop is now running for XTD10 with the full design firmware
Approximately 40 ion pumps were locally test and are no under PLC control
Almost all valves were locally tested and are also under PLC control
XGM is connected to its own PLC currently (integrating Vacuum and gas supply)
CAS
A disucssion on the details of Gotthard integration will happen with FXE after this meeting