Subject: Issue 

The status of the XTD2 attenuators has been checked during the experiment last week and many were found to cause disturbances in the wavefront ranging from mild to severe.

Attachment 1: No attenuator
Attachment 2: 75 um CVD - Fringes visible in beam
Attachment 3: 150 um CVD - Strong fringes in beam
Attachment 4: 300 um CVD - Looks more or less ok
Attachment 5: 600 um CVD - Weak distortion in the beam profile
Attachment 6: 1200 um CVD - Ok
Attachment 7: 2400 um CVD - Ok
Attachment 8: 500 um Si - Not ok

Attachment 1: Screenshot-from-2024-02-26-07-28-43_no_att.png  201 kB  | Hide | Hide all | Show all
Screenshot-from-2024-02-26-07-28-43_no_att.png
Attachment 2: Screenshot-from-2024-02-26-07-31-33_75um_CVD.png  212 kB  | Show | Hide all | Show all
Attachment 3: Screenshot-from-2024-02-26-07-31-16_150um_CVD.png  212 kB  | Show | Hide all | Show all
Attachment 4: Screenshot-from-2024-02-26-07-32-32_300um_CVD.png  214 kB  | Hide | Hide all | Show all
Screenshot-from-2024-02-26-07-32-32_300um_CVD.png
Attachment 5: Screenshot-from-2024-02-26-07-33-34_600um_CVD.png  211 kB  | Hide | Hide all | Show all
Screenshot-from-2024-02-26-07-33-34_600um_CVD.png
Attachment 6: Screenshot-from-2024-02-26-07-34-32_1200um_CVD.png  200 kB  | Show | Hide all | Show all
Attachment 7: Screenshot-from-2024-02-26-07-35-18_2400um_CVD.png  215 kB  | Show | Hide all | Show all
Attachment 8: Screenshot-from-2024-02-26-07-36-08_500um_Si.png  239 kB  | Show | Hide all | Show all
ELOG V3.1.4-7c3fd00