Shift summary 2024-02-23 07:00 - 2024-02-24 10:00
We got self-seeding at 8.5 keV very quickly after changeover from 10.5 keV operation finished at 2024-02-23 07:00.
Pulse energy ~ 600 uJ.
Progress is in general good. Most of planned tasks for the day are done.
We called BKR whether we can get a bit more energy/pulse this morning, but it appears difficult. Otherwise, having a bit more energy would be helpful to have enough signal-to-noise ratio for X-ray imaging.
Achievements:
- Insert nanofocus lens, pump IC1 sample chamber into vacuum
- Establish X-ray axis, measure source point and divergence
- Set up the CRL scheme overfilling CRL4b nanofocus (the settings used in Feb at 8.2 keV were CRL1 arm 3,5 and CRL2 arm 1)
- Bring the imaging systems to the X-ray axis
- Focus and calibrate the x-ray spectrometers
- Laser-xray timing verified on YAG
- DAMNIT setup
- Nanofocus imaging optimization (Z-scans) with Cu 25um wire and Siemens star
- Best focus was identified
- Sample alignment
|