Message ID: 220     Entry time: 06 Dec 2024, 02:41
Author: Jörg Hallmann 
Group: MID 
Subject: Shift summary 

optimization of the timing of the involved components (laser, cameras, FEL)
generation of the first bubbles in water

issue
several times, the beam lost the position in the tunnel - it disappeared on the last tunnel imager. based on the motor parameter of the mirrors, no motion caused this. the position information of the XGM also did not show any strange values

Attachment 1: 2024-12-06Bubble0003.png  126 kB  | Show | Show all