OPERATION-2024 logbook, Contact: F.Wolff-Fabris, A.Galler, H.Sinn
Not logged in
List
|
Message ID:
113
Entry time:
26 May 2024, 23:23
Author:
Romain Letrun
Group:
SPB
Subject:
Shift summary
X-ray delivery
6.0 keV, up to 202 pulses at 564 kHz, 1.8-1.9 mJ.
Stable delivery except for downtime at start of shift (until 7:15) and two more hours in the morning.
Optical laser delivery
770 nm, up to 202 pulses at 564 kHz.
Stable delivery.
Achievements/Observations
Collected time-resolved diffraction from gold and gold-platinum nanorods at multiple laser fluences.
Issues
Vacuum spike in EHU_PSLIT section.
DAMNIT backend process stuck. A couple of Maxwell nodes were unaccessible. Solved by DOC and DA OCD.
Issue with two AGIPD modules noticed around 21:20. Could not be recovered before end of the shift. To be further investigated tomorrow morning.