10
Entry time:
02 Feb 2024, 23:31
Author:
Romain Letrun
Group:
SPB
Subject:
Shift summary
X-ray delivery
1-64 pulses at 10 keV, ~1.1 mJ.
Overall stable delivery.
Optical laser delivery
NA
Achievements/Observations
Measured flat fields for JUNGFRAU for all configurations. Detector program completed.
Issues
Mishap of lit frame finder with custom bunch patter.
Apparent issue to process JUNGFRAU darks caused by lack of disk space. Solved by DOC/CAL.
Ghost run in myMdC upsetting the run controller. Solved by DOC and cause under further investigation.