Group Selection Page HELP Controls Group Data Analysis Group ITDM WP76 DET Vacuum EEE WP78 WP74 FXE SCS SPB MID HED SQS SXP Sample Environment Operation PSPO XO TS Migrated2Zulip
OPERATION-2025 OPERATION-2024 OPERATION-2023 OPERATION-2022 OPERATION-2021 OPERATION-2020 OPERATION-2019 SASE1-2018 SASE1-2017 Experiment data
  OPERATION-2023 logbook, Contact: F.Wolff-Fabris, A.Galler, L.Samoylova, H.Sinn, Page 9 of 24  Not logged in ELOG logo
ID Date Author Group Subjectdown Text Attachments
  190   07 May 2023, 02:23 Jan-Etienne PudellMIDShift summaryWe had stable x-ray delivery with 120µJ
and up to 300 pulses.

Successful user data acquisition
  
  194   08 May 2023, 02:38 Jan-Etienne PudellMIDShift summaryStable beam delivery with 23keV and 140µJ
at 2.2, 1.1 and 0.55MHz

 
  
  196   09 May 2023, 23:09 Romain LetrunSPBShift summaryX-ray delivery


9.3 keV, 1.8 mJ, 202 pulses
most fo the day. Pronounced (~30-40%) slope
  
  197   10 May 2023, 09:51 karen appelHEDShift summaryfor 9th of May - 10th of May:
user experiment 2740 , first users with DIPOLE100-X
long pulse laser
  
  198   10 May 2023, 23:23 Romain LetrunSPBShift summaryX-ray delivery


9.3 keV, 1.6 mJ, 202 pulses
msot of the day.
Slope across
  
  199   11 May 2023, 05:07 Konopkova ZuzanaHEDShift summarybeam parameters: 18 keV, 1 pulse on demand,
400 uJ

achieved:
  
  201   11 May 2023, 23:48 Romain LetrunSPBShift summaryX-ray delivery


9.3 keV, 1.4-1.8 mJ and
12 keV, 1.1 mJ. 202 pulses most of the day.
Reduced
  
  203   12 May 2023, 23:21 Romain LetrunSPBShift summaryX-ray delivery


9.3 keV, 1.8 mJ, 202 pulses
most of the day.
Attempted tuning
  
  206   18 May 2023, 18:41 Tokushi SatoSPBShift summaryX-ray delivery


9.3 keV, ~1 mJ, 1-30 pulses,
stable delivery


Optical
  
  207   19 May 2023, 18:39 Tokushi SatoSPBShift summaryX-ray delivery


9.3 keV, 800 uJ, 1-200
pulses, stable delivery


Optical
  
  208   21 May 2023, 18:38 Tokushi SatoSPBShift summaryX-ray delivery


9.3 keV, 800 uJ, 1-200
pulses, stable delivery


Optical
  
  209   25 May 2023, 01:59 Jörg HallmannMIDShift summaryoptimization of seeding ongoing

tasks achieved during alignment:

- polarizer aligned
  
  210   25 May 2023, 06:35 Tokushi SatoSPBShift summaryX-ray delivery


10.7 keV, 1.2 mJ,
1-200 pulses, stable delivery


Optical
  
  212   28 May 2023, 23:15 Fernando ArdanaFXEShift summaryUser proposal 3273:


X-ray delivary

We
use several deliveraly modes:

Continous
  
  213   30 May 2023, 23:02 Romain LetrunSPBShift summaryX-ray delivery


10.7 keV, up to 339 pulses
at 1.1 MHz.
Large slope through
  
  215   31 May 2023, 23:15 Romain LetrunSPBShift summaryX-ray delivery


10.65 keV, 128 pulses at
1.13 MHz and 16 pusles at 141 kHz.
Slope
  
  216   01 Jun 2023, 12:10 Konopkova ZuzanaHEDShift summaryX-ray parameters: 20 keV (20080 eV from
HIREX), 352 pulses, cca 250 uJ


changed setup to diamond
  
  217   01 Jun 2023, 23:27 Romain LetrunSPBShift summaryX-ray delivery


10.65 keV, 128 pulses at
1.13 MHz and 16 pusles at 141 kHz.
Overall
  
  219   02 Jun 2023, 23:34 Romain LetrunSPBShift summaryX-ray delivery


10.65 keV, 128 pulses at
1.13 MHz, 1.6-1.7 mJ.
Overall
  
  220   03 Jun 2023, 09:42 Thomas PrestonHEDShift summaryX-ray parameters: 20 keV,  352 pulses,
ca 300 uJ


running user samples.


experiment
  
ELOG V3.1.4-7c3fd00