Group Selection Page
HELP
DOC
Controls Group
Data Analysis Group
ITDM
WP76
DET
Vacuum
XRO
EEE
WP78
WP74
FXE
SCS
SPB
MID
HED
SQS
SXP
Sample Environment
Photon Commissioning Team
Operation
PSPO
XO
TS
|
OPERATION-2024
OPERATION-2023
OPERATION-2022
OPERATION-2021
OPERATION-2020
OPERATION-2019
SASE1-2018
SASE1-2017
Experiment data
|
OPERATION-2023 logbook, Contact: F.Wolff-Fabris, A.Galler, L.Samoylova, H.Sinn |
Not logged in |
|
|
Message ID: 5
Entry time: 21 Jan 2023, 16:38
|
Author: |
Jan Gruenert |
Group: |
XPD |
Subject: |
Analyze and quantify the mispositioning of the new 4mm-aperture behind the undulator |
|
|
Goal: Analyze and quantify the mispositioning of the new 4mm-aperture behind the undulator
Positions in tunnel:
- ABSP4.2422.SA2 = ABSP4.CELL37.SA2 L_z position 2422.558m
- Last closed undulator for this test is cell16 at 2294m (at end of segment) = SR radiation source point
- IMGTR = 2576m (BT=181.1m, PD=582.0m).
- IMGSR = 2586m (BT=191.6m, PD=591.5m).
- IMGFEL = 2637m (BT=242.0m, PD=642,8m).
- Sequence: end-of-cell16 -- ABSP4 -
Measurements:
- IMGTR : dX=15.15-8.25=6.9mm. dY=17-9.8=7.2mm. Aperture shadow mean diameter = 7.1mm
- IMGSR : Aperture shadow mean diameter = ca. 8.5 mm
- IMGFEL : Aperture shadow mean diameter = 9.0 mm.
The handover cross is at dy = +1.0mm (up) and dx = -2.6mm (left) relative to the apparent center of the aperture shadow.
Comments to the screenshots:
- The handover cross on the IMGFEL cannot be seen simultaneously with the weak SR background because it has the color scaled to high intensity beam.
- The FEL beam spot is almost perfectly centered on the handover cross.
Calculations:
IMGFEL |
Px / mm |
Position / px |
Position / mm |
|
|
|
|
|
|
|
|
|
dx |
0.715 |
3.56 |
2.5454 |
|
|
|
|
|
|
|
|
|
dy |
1.036 |
0.97 |
1.00492 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tunnel positions |
L_z |
renormalized |
aperture shadow diameter / mm |
theor. Shadow diameter |
apparent offset in x / mm |
apparent offset in y / mm |
apparent offset in x / mm |
apparent offset in y / mm |
required offset to send the FEL on the same handover cross position but through the center of the 4mm aperture |
|
|
|
Cell1 upstream end |
2197 |
-97 |
|
|
|
|
|
|
|
|
|
|
Cell16 downstream end |
2294 |
0 |
0 |
0.00 |
0 |
0 |
0 |
0 |
-1.99949886889298 |
|
|
|
ABSP4 |
2422.558 |
129 |
4 |
4.00 |
-0.97 |
0.37 |
-1.16 |
0.44 |
|
|
|
|
IMGTR |
2576 |
282 |
7.1 |
8.77 |
|
|
|
|
|
|
|
|
IMGSR |
2586 |
292 |
8.5 |
9.09 |
|
|
|
|
|
|
|
|
IMGFEL |
2637 |
343 |
9 |
10.67 |
-2.6 |
1 |
-2.6 |
1 |
|
|
|
|
Conclusions:
The 4mm aperture is misplaced by 0.97mm (x) and 0.37mm (y).
It should be moved dx = -0.97mm and dy = 0.37mm, or the FEL has to be made on a different trajectory. |
|
|
|
|
|
|
|