Message ID: 5     Entry time: 21 Jan 2023, 16:38
Author: Jan Gruenert 
Group: XPD 
Subject: Analyze and quantify the mispositioning of the new 4mm-aperture behind the undulator 

Goal: Analyze and quantify the mispositioning of the new 4mm-aperture behind the undulator

Positions in tunnel:

  • ABSP4.2422.SA2 = ABSP4.CELL37.SA2 L_z position 2422.558m
  • Last closed undulator for this test is cell16 at 2294m (at end of segment) = SR radiation source point
  • IMGTR = 2576m (BT=181.1m, PD=582.0m).
  • IMGSR = 2586m (BT=191.6m, PD=591.5m).
  • IMGFEL = 2637m (BT=242.0m, PD=642,8m).
  • Sequence: end-of-cell16 -- ABSP4 -

Measurements:

  • IMGTR : dX=15.15-8.25=6.9mm. dY=17-9.8=7.2mm. Aperture shadow mean diameter = 7.1mm
  • IMGSR : Aperture shadow mean diameter = ca. 8.5 mm
  • IMGFEL : Aperture shadow mean diameter = 9.0 mm.
    The handover cross is at dy = +1.0mm (up) and dx = -2.6mm (left) relative to the apparent center of the aperture shadow.

Comments to the screenshots:

  • The handover cross on the IMGFEL cannot be seen simultaneously with the weak SR background because it has the color scaled to high intensity beam.
  • The FEL beam spot is almost perfectly centered on the handover cross.

Calculations:

IMGFEL Px / mm Position / px Position / mm                  
dx 0.715 3.56 2.5454                  
dy 1.036 0.97 1.00492                  
                         
Tunnel positions L_z renormalized aperture shadow diameter / mm theor. Shadow diameter apparent offset in x / mm apparent offset in y / mm apparent offset in x / mm apparent offset in y / mm required offset to send the FEL on the same handover cross position but through the center of the 4mm aperture      
Cell1 upstream end 2197 -97                    
Cell16 downstream end 2294 0 0 0.00 0 0 0 0 -1.99949886889298      
ABSP4 2422.558 129 4 4.00 -0.97 0.37 -1.16 0.44        
IMGTR 2576 282 7.1 8.77                
IMGSR 2586 292 8.5 9.09                
IMGFEL 2637 343 9 10.67 -2.6 1 -2.6 1      

 

Conclusions:

The 4mm aperture is misplaced by 0.97mm (x) and 0.37mm (y).
It should be moved dx = -0.97mm and dy = 0.37mm, or the FEL has to be made on a different trajectory.

Attachment 1: JG_2023-01-21_16-06-48.png  163 kB  | Hide | Hide all | Show all
JG_2023-01-21_16-06-48.png
Attachment 2: JG_IMGFEL_2023-01-21_16-21-01.png  455 kB  | Show | Hide all | Show all
Attachment 3: IMGFEL_no_cross_2023-01-21_16-27-22.png  327 kB  | Hide | Hide all | Show all
IMGFEL_no_cross_2023-01-21_16-27-22.png
Attachment 4: IMGFEL_with_cross_2023-01-21_16-30-16.png  284 kB  | Hide | Hide all | Show all
IMGFEL_with_cross_2023-01-21_16-30-16.png
ELOG V3.1.4-7c3fd00