Group Selection Page HELP DOC Controls Group Data Analysis Group ITDM WP76 DET Vacuum XRO EEE WP78 WP74 FXE SCS SPB MID HED SQS SXP Sample Environment Photon Commissioning Team Operation PSPO XO TS
OPERATION-2024 OPERATION-2023 OPERATION-2022 OPERATION-2021 OPERATION-2020 OPERATION-2019 SASE1-2018 SASE1-2017 Experiment data
  OPERATION-2023 logbook, Contact: F.Wolff-Fabris, A.Galler, L.Samoylova, H.Sinn  Not logged in ELOG logo
Message ID: 44     Entry time: 19 Feb 2023, 05:29
Author: Motoaki Nakatsutsumi, Carsten Baehtz, Olver Humphries 
Group: HED 
Subject: Shift summary - night shift 2023-02-18 

18 Feb 2023, 23:37 Together with the last shift members, we continued shooting laser on Cu 25 um thick wire for another 2 hours. We got excellent quality x-ray imaging with a series of time delay up to several ns (eLog ID 39).  X-ray imaging is now commissioned. The magnification was x7.5.

19 Feb 2023, 01:30 We tried to go to x20, but we couldn't find the x-ray beam. We even put the burn paper in front of the Optique Peter to verify the x-ray position, but still we couldn't see anything on the Optique Peter. Probably the x-ray was too weak. This activity was done with CRL4b "in", so the beam size was big on the Optique Peter. Next step is to remove the CRL3b and do the same exercise.

19 Feb 2023, 03:00 We switch to CRL4a (upsteam of the sample) and aligned.

19 Feb 2023, 03:30 In parallel, PAM work: added 10 mm thick SF57 on the spectral arm. Time = 0 is established for both spatial and spectral arm. See eLog ID 33.

19 Feb 2023, 06:10 Put a mesh 2000 lines and do the focal scan. 1.5 % transmission. Att.1. The focus is around Axis_5 = 95-100 mm.

  Pos (Axis_5)  
#243 55  
#244 35  
#245 15  
#246 -5  
#247 -15  
#248 +75  
#249 +85  
#250 +95  
#251 +105  
     
     

 

Attachment 1: Foc_scan_2000l_mm.PNG  1.162 MB  Uploaded 19 Feb 2023, 06:48  | Hide | Hide all
Foc_scan_2000l_mm.PNG
ELOG V3.1.4-7c3fd00