Message ID: 346     Entry time: 18 Sep 2023, 19:14
Author: Yifeng Jiang 
Group: FXE 
Subject: Issue 
  • We found that the x-ray pulse energy dropped a lot when we changed the undulator from 5.5 keV to 5.45 keV. We called BKR to optimise it (attachment 1)
    => There is a problem with the phase shifter of the undulator. It stacks sometime. If the x-ray intensity drops, we need to ask BKR to optimise it.
    => We were suggested not to change the undulator value by 100 eV. 5 - 10 eV step should be fine.

On the other hand, we had a user experiment 3435 Feb 2023, and we could perform photon energy scan from 5.7 keV to 6.1 keV without problem. (attachment 2)

Attachment 1: 11111.PNG  71 kB  Uploaded 18 Sep 2023, 20:19  | Hide | Hide all | Show all
11111.PNG
Attachment 2: 3435.PNG  53 kB  Uploaded 18 Sep 2023, 20:32  | Show | Hide all | Show all