Entry time: 02 Oct 2014, 10:35
|
Author: |
Frank Babies |
Type: |
Configuration |
Category: |
N.A.T. MCH |
Subject: |
base configuration from the MCH |
|
|
INFO - MCH configuration CFG V2.14 for V2.14.1 Final (15:39:47 Jul 25 2013) ok
MCH global parameter:
---------------------
remote interfaces:
RMCP access: enabled
telnet access: enabled
WEB access: enabled
IP address source Mgmt: board configuration
RMCP session activity timeout minutes: 0 min
RMCP session activity timeout seconds: 60 sec
default fan level: 30 percent
MCH configuration flags:
Enable backward compatibility V2.4: no
Enable alternative cooling scheme: no
Control rear transition module fans: no
Enable Telnet inact timeout (600s): no
Shelf manager parameter:
------------------------
ShM configuration flags:
allow shelf FRU invalid: yes
temperature management: enabled
emergency shutdown on critical ev.: disabled
emergency shutdown on non recov ev.: disabled
send SEND_MSG confirmation to SMS: no
use external shelf manager: no
Carrier manager parameter:
--------------------------
carrier number default: 0
quiesced event timeout: 10 sec
CM configuration flags:
allow carrier FRU invalid: yes
overrule carrier FRU: no
shutdown system if MCH goes down: no
enable Clock E-keying: no
CM debug:
IPMI: disabled
FRU: disabled
E-keying: disabled
sensor: disabled
event: disabled
power module: disabled
cooling unit: disabled
CM/ShM interface: disabled
debugging FRU: 0
SEL parameter:
--------------
SEL configuration flags:
'keep on read': disabled
allocate SEL in non-volatile RAM: yes
ignore 'version change' sensor: yes
Ethernet switch parameter:
--------------------------
configuration source: load from FLASH
ignore backplane FRU info: no
CLK module parameter:
---------------------
CLK module configuration source: load from FLASH
PCIe parameter:
---------------
PCIe Virtual Switch configuration
change via web-interface
VS # | Host | NT-Host | AMC1 AMC2 AMC3 AMC4 AMC5 AMC6 AMC7 AMC8 AMC9 AMC10 AMC11 AMC12
0 01 none X X X X X X X X X X X X
1
2
3
4
5
Upstream slot power up delay: 15 sec
PCIe power up delay for AMC: 10 sec
PCIe configuration flags:
100 MHz spread spectrum: disabled
hot plug support: enabled
PCIe early ekey (before payload): enabled
PCIe clustering: enabled
NTP parameter:
--------------
NTP server IP: 131.169.40.65
NTP 'check for time' delay minutes: 0 min
NTP 'check for time' delay hours: 0 h
NTP local time offset: 2 h
NTP configuration flags:
NTP client: enabled
NTP client protocol: Time Protocol
DHCP Configuration:
-------------------
host name: <empty>
flags: 0x00
|