Group Selection Page
HELP
DOC
Controls Group
Data Analysis Group
ITDM
WP76
DET
Vacuum
XRO
EEE
WP78
WP74
FXE
SCS
SPB
MID
HED
SQS
SXP
Sample Environment
Photon Commissioning Team
Operation
PSPO
XO
TS
|
General electronics
MicroTCA
EEE Electronics Lab
EEE Rack Room
|
MicroTCA Logbook |
Not logged in |
|
|
Message ID: 151
Entry time: 02 Oct 2014, 10:35
|
Author: |
Frank Babies |
Type: |
Configuration |
Category: |
N.A.T. MCH |
Subject: |
base configuration from the MCH |
|
|
INFO - MCH configuration CFG V2.14 for V2.14.1 Final (15:39:47 Jul 25 2013) ok
MCH global parameter:
---------------------
remote interfaces:
RMCP access: enabled
telnet access: enabled
WEB access: enabled
IP address source Mgmt: board configuration
RMCP session activity timeout minutes: 0 min
RMCP session activity timeout seconds: 60 sec
default fan level: 30 percent
MCH configuration flags:
Enable backward compatibility V2.4: no
Enable alternative cooling scheme: no
Control rear transition module fans: no
Enable Telnet inact timeout (600s): no
Shelf manager parameter:
------------------------
ShM configuration flags:
allow shelf FRU invalid: yes
temperature management: enabled
emergency shutdown on critical ev.: disabled
emergency shutdown on non recov ev.: disabled
send SEND_MSG confirmation to SMS: no
use external shelf manager: no
Carrier manager parameter:
--------------------------
carrier number default: 0
quiesced event timeout: 10 sec
CM configuration flags:
allow carrier FRU invalid: yes
overrule carrier FRU: no
shutdown system if MCH goes down: no
enable Clock E-keying: no
CM debug:
IPMI: disabled
FRU: disabled
E-keying: disabled
sensor: disabled
event: disabled
power module: disabled
cooling unit: disabled
CM/ShM interface: disabled
debugging FRU: 0
SEL parameter:
--------------
SEL configuration flags:
'keep on read': disabled
allocate SEL in non-volatile RAM: yes
ignore 'version change' sensor: yes
Ethernet switch parameter:
--------------------------
configuration source: load from FLASH
ignore backplane FRU info: no
CLK module parameter:
---------------------
CLK module configuration source: load from FLASH
PCIe parameter:
---------------
PCIe Virtual Switch configuration
change via web-interface
VS # | Host | NT-Host | AMC1 AMC2 AMC3 AMC4 AMC5 AMC6 AMC7 AMC8 AMC9 AMC10 AMC11 AMC12
0 01 none X X X X X X X X X X X X
1
2
3
4
5
Upstream slot power up delay: 15 sec
PCIe power up delay for AMC: 10 sec
PCIe configuration flags:
100 MHz spread spectrum: disabled
hot plug support: enabled
PCIe early ekey (before payload): enabled
PCIe clustering: enabled
NTP parameter:
--------------
NTP server IP: 131.169.40.65
NTP 'check for time' delay minutes: 0 min
NTP 'check for time' delay hours: 0 h
NTP local time offset: 2 h
NTP configuration flags:
NTP client: enabled
NTP client protocol: Time Protocol
DHCP Configuration:
-------------------
host name: <empty>
flags: 0x00
|