Group Selection Page HELP DOC Controls Group Data Analysis Group ITDM WP76 DET Vacuum XRO EEE WP78 WP74 FXE SCS SPB MID HED SQS SXP Sample Environment Photon Commissioning Team Operation PSPO XO TS
General electronics MicroTCA EEE Electronics Lab EEE Rack Room
  MicroTCA Logbook  Not logged in ELOG logo
Message ID: 151     Entry time: 02 Oct 2014, 10:35
Author: Frank Babies 
Type: Configuration 
Category: N.A.T. MCH 
Subject: base configuration from the MCH 

INFO - MCH configuration CFG V2.14 for V2.14.1 Final (15:39:47 Jul 25 2013) ok

MCH global parameter:
---------------------
remote interfaces:
  RMCP access:                         enabled
  telnet access:                       enabled
  WEB access:                          enabled
IP address source Mgmt:                board configuration
RMCP session activity timeout minutes: 0 min
RMCP session activity timeout seconds: 60 sec
default fan level:                     30 percent
MCH configuration flags:
  Enable backward compatibility V2.4:  no
  Enable alternative cooling scheme:   no
  Control rear transition module fans: no
  Enable Telnet inact timeout (600s):  no

Shelf manager parameter:
------------------------
ShM configuration flags:
  allow shelf FRU invalid:             yes
  temperature management:              enabled
  emergency shutdown on critical ev.:  disabled
  emergency shutdown on non recov ev.: disabled
  send SEND_MSG confirmation to SMS:   no
  use external shelf manager:          no

Carrier manager parameter:
--------------------------
carrier number default:                0
quiesced event timeout:                10 sec
CM configuration flags:
  allow carrier FRU invalid:           yes
  overrule carrier FRU:                no
  shutdown system if MCH goes down:    no
  enable Clock E-keying:               no

CM debug:
  IPMI:                                disabled
  FRU:                                 disabled
  E-keying:                            disabled
  sensor:                              disabled
  event:                               disabled
  power module:                        disabled
  cooling unit:                        disabled
  CM/ShM interface:                    disabled
  debugging FRU:                       0

SEL parameter:
--------------
SEL configuration flags:
  'keep on read':                      disabled
  allocate SEL in non-volatile RAM:    yes
  ignore 'version change' sensor:      yes

Ethernet switch parameter:
--------------------------
 configuration source:  load from FLASH
 ignore backplane FRU info:            no

CLK module parameter:
---------------------
 CLK module configuration source:      load from FLASH

PCIe parameter:
---------------
PCIe Virtual Switch configuration
change via web-interface
 VS # | Host | NT-Host | AMC1 AMC2 AMC3 AMC4 AMC5 AMC6 AMC7 AMC8 AMC9 AMC10 AMC11 AMC12
  0     01     none        X    X    X    X    X    X    X    X    X    X     X     X
  1
  2
  3
  4
  5
Upstream slot power up delay:          15 sec
PCIe power up delay for AMC:           10 sec
PCIe configuration flags:
  100 MHz spread spectrum:             disabled
  hot plug support:                    enabled
  PCIe early ekey (before payload):    enabled
  PCIe clustering:                     enabled

NTP parameter:
--------------
NTP server IP:                         131.169.40.65
NTP 'check for time' delay minutes:    0 min
NTP 'check for time' delay hours:      0 h
NTP local time offset:                 2 h
NTP configuration flags:
  NTP client:                          enabled
  NTP client protocol:                 Time Protocol

DHCP Configuration:
-------------------
host name:                             <empty>
flags:                                 0x00
 

ELOG V3.1.4-7c3fd00